Mounting
03.00|1341130_ROTA NCR-A |en
29
Mounting
Installing and connecting
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
CAUTION
Danger of injury due to sharp edges and rough or slippery
surfaces
•
Wear personal protective equipment, particularly protective
gloves.
1 Checking the chuck mount
3 Check the function
Checking the chuck mounting
Checking the spindle nose for mounting the chuck flange
The machine side has to be aligned prior to the flange being
installed in order to achieve high true running accuracy for the
chuck. To do this, check the contact surfaces on the spindle for
axial and concentric run-out using a dial indicator (see Fig. "Chuck
assembly" - A).
There should be a maximum concentricity error in the centering
of the mount of 0.005 mm and a maximum axial run-out error in
the contact surfaces of 0.005 mm. The flat surface of the spindle
must also be checked for flatness using a straight edge.
Make sure that the surface area of the flat surface is deburred at
the bore holes and is clean.
5
5.1
5.2