Maintenance
04.00|ROTA FSW |en
35
Storing the ROTA FSW Chuck quick-change
Store the ROTA FSW chuck quick-change in its original packaging
under the following conditions:
Do not keep outdoors.
Store in a dry and dust-free place.
Do not expose to any aggressive media.
Protect from sunlight.
Avoid mechanical vibrations.
Stocking temperature: 15 to 35°C.
Relative air humidity: max. 60%.
When storing for longer than 3 months:
Check the general condition of all parts and the packaging
regularly.
If required, refresh preservation or renew.
Re-storing the ROTA FSW chuck quick-change
Thoroughly clean the jaw quick-change ROTA FSW before
reinserting, oil and/or grease (see chapter "Disassemble and
assemble the ROTA FSW chuck quick-change"
).
Pack ROTA FSW chuck quick-change in air-tight film.
The chuck quick-change ROTA FSW must be stored in a secure
position.
If that is not guaranteed, use a suitable container for the ROTA
FSW or equip the shelf with a surrounding safety border.
Disassembling and assembling the ROTA FSW Chuck quick-
change
The item numbers specified for the corresponding individual
components relate to chapter drawings.
The ROTA FSW chuck quick-change must only be disassembled
when not installed.
• Remove the two set-screws (Pos. 8) and remove the
compression springs (Pos. 26) and the indicator pins (Pos. 6).
• Use a sliding hammer to remove the cylindrical pin (Pos. 22)
from the housing (Pos. 1) via the pulling off thread.
• Rotate the actuating screw (Pos. 5) counter-clockwise from the
lever (Pos. 4) and remove it.