Assembly
22
10.00 | PSH | Assembly and operating manual | en | 389331
Dimensions of the compressed air connections
Item Mounting
PSH
22
32
42
52
1
Thread in the main air connections:
Metric version
M5
G 1/8" G 1/8" G 1/8"
Inch version
#10-32 G 1/8" G 1/8" G 1/8"
Max. depth of engagement
from locating surface [mm]
6
6
8
8
2, 3 Hose-free direct
connection
M4
M5
M5
M5
The following possibilities are available for throttling the gripper:
• Use of one-way flow control valves
• Minimizing the diameter of the air supply holes in the adapter
plate (Ø1.0 for PSH 22 / Ø1.4 for PSH 32)
• Screwing the throttles (22/32) into the threads used for the
hose-free direction connection,
for item numbers see
5.3 Mounting the sensor
NOTE
Observe the assembly and operating manual of the sensor for
mounting and connecting.
The product is prepared for the use of sensors.
• For the exact type designations of suitable sensors, please see
catalog datasheet and Link Übersicht Sensoren.
• For technical data for the suitable sensors, see assembly and
operating manual and catalog datasheet.
– The assembly and operating manual and catalog datasheet
are included in the scope of delivery for the sensors and are
available at schunk.com.
• Information on handling sensors is available at schunk.com or
from SCHUNK contact persons.
5.3.1 Overview of sensors
Designation
PSH
22
32
42
52
Magnetic switch MMS 30
X
X
X
X
Inductive proximity switch IN 80
X
X
X
X
Flexible position sensor FPS-S 13
X
X
X