6.5.4 incremental measuring system LE100
This measuring system can only be used in the PPU-E 15.
Description
LE100
Operating voltage [VDC]
5 ± 5%
Output signal
Sin, Cos
Signal amplitude [Vss]
1 ±10%
Offset sine/cosine [V]
2.5 ±0.5%
Signal period [µm]
1000
Periodical reference signal [mm]
20
Distance between reading head and
measuring tape [mm]
0.05 to 0.2
Pin
assignment
1
5VSense
2
0V Sense
3
ref-
4
ref+
5
cos-
6
cos+
7
sin+
8
sin-
9
-
10
GND
11
-
12
5V
13
-
14
-
15
-