Assembly
02.00 | OPS | Assembly and Operating manual | en | 389668
19
Circuit diagram sensor PNP-Version
Item Designation
Color
1
+24V
Brown
2
Signal
Black
3
GND
Blue
4
Load
Designation
Value
Power supply [VDC]
10 ... 30 (Remaining ripple max. 10%)
Power demand [mA]
Max. 7.5 (wihtout load at 24 V)
Voltage drop [V]
Max. 3,6
Output
PNP switching
Max. power output [mA] 180 (resistive load); short circuit proof
Output signal
OPS locked – transistor leading
OPS unlocked – transistor not leading