Montage- und Betriebsanleitung
Assembly and Operating Manual
MMS 22-IOL
Magnetschalter mit IO-Link
Schnittstelle
Magnetic Switch with IO-Link
Interface
Dear customer,
thank you for trusting our products and our
family-owned company, the leading technology
supplier of robots and production machines.
Our team is always available to answer any
questions on this product and other solutions.
Ask us questions and challenge us. We will find
a solution!
Best regards,
Your SCHUNK team
Document number: 1361309
Edition: 03.00 | 08/12/2022 | de - en
Copyright:
This manual is protected by copyright. The
author is SCHUNK GmbH & Co. KG. All rights
reserved.
Technical changes:
We reserve the right to make alterations for the
purpose of technical improvement.
SCHUNK GmbH & Co. KG
Spann- und Greiftechnik
Bahnhofstr. 106 – 134
D-74348 Lauffen/Neckar
Tel.+49-7133-103-0
Fax +49-7133-103-2399
[email protected]
schunk.com
6.2.2 LED flashes at 10Hz and [5] Teach Error is displayed under
Sensor Command Reply
Possible cause
Corrective action
Poor magnetic field -> sensor mounted
at incorrect position
Mount sensor in the correct position
as per the gripper's Assembly and
Operating Manual
6.3 In SIO mode
6.3.1 Sensor not operating
Ø
Check whether the sensor cable is broken.
Ø
Check whether the voltage at the sensor is between 18 - 30 VDC.
Ø
Check whether the LED lights up at the position to be sensed and that the
sensor is operating.
NOTE
If the LED does not light up or the sensor is not operating, contact SCHUNK
Service.