Assembly and settings
44
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637
2. Loosen clamping spindle (4) and remove the switching cam (6)
for inductive sensing from the base jaw by turning the
adjusting spindle (5).
3. Slide control cam (7) from the mounting kit into the base jaw.
✓
Ensure that the higher front side of the control cam (6) is
pointing outwards.
4. Screw the switching cam (7) into the base jaw by turning the
adjusting spindle (5) until the adjustment dimension I3 is
reached
.
5. Fix the control cam (7) with the clamping spindle (4). It must
not be possible to move the control cam after assembly.
6. Slide the sensor (1) to the stop into the bracket (2).
7. Tighten the screw (3) on the bracket (2).
Tightening torque: 0.2 Nm
8. Connect the sensor, see assembly and operating manual of the
sensor.
5.4.13 Mount the flexible position sensor FPS
The flexible position sensor FPS consists of an evaluation unit and
one of the following sensors:
• MMS 22-A-5V
• FPS-S M8
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
5.4.13.1 Mounting the MMS 22-A-5V
Note: In order to mount the sensor MMS 22-A-5V, no additional
attachment kit is required.
1. Assembling the sensor,
2. Connect the control unit output and adjust the sensor (see
assembly and operating manual of the sensor).