![SCHUNK HLM 100 Assembly And Operating Manual Download Page 27](http://html1.mh-extra.com/html/schunk/hlm-100/hlm-100_assembly-and-operating-manual_1215731027.webp)
Troubleshooting
02.00 | HLM | Assembly and operating manual | en | 389497
27
6 Troubleshooting
6.1 Module does not move
Possible cause
Corrective action
Pressure drops below minimum.
Check air supply. Link Luftanschlüsse
Compressed air lines switched.
Check compressed air lines. Link
Luftanschlüsse
6.2 End position signal not present
Possible cause
Corrective action
Proximity switch defective or set incorrect.
Adjust sensor or if necessary change sensor.,
Link Endlagen
Cable breakage.
Change sensor.
6.3 Linear module proposes at the end positions
Possible cause
Corrective action
Damping wrong adjustet.
Adjust stop screw.
Shock absorber defective.
Change the shock absorber.
Stroke speed too high.
Check / reduce stroke speed with ventilation
valves.
Change defective exhaust ait throttle if
necessary.
6.4 Payload swings in the final position?
Possible cause
Corrective action
Stroke speed too high.
Check / reduce stroke speed with ventilation
valves.
Change defective exhaust ait throttle if
necessary.
Bad damping.
Adjust damping (stop screw). Assembly and
Settings
Unfavorable installation.
Check construction.
CLM size too small
Use larger CLM size.