Operation
18
02.00 | GSW-V | Assembly and Operating Manual | en | 389116
5 Operation
Sectional view of GSW-V
Holding the
workpiece
CAUTION
Risk of injury due to the workpiece falling
If the workpiece is very dirty or uneven, it may fall down.
•
Only grip workpieces with surfaces that are as clean and even
as possible.
Ø
Apply the vacuum suction unit (4) of the GSW-V to the
workpiece.
✓
The vacuum suction unit (4) is slightly flexible so that it can
be used for Z-compensation.
Ø
Switch on the compressed air or cooling lubricant supply of the
toolholder.
✓
The compressed air or lubricant enters the Venturi nozzle (2)
through the media inlet (1).
✓
This causes the Venturi nozzle (2) to generate a vacuum in
the intake duct (5).
✓
The workpiece is now securely held.
Note: During holding, the gripper continuously supplies
coolant or compressed air via the outlet port (3).
Ø
Position the workpiece using the GSW-V.