Troubleshooting
03.00 | GSW-B-AGE | Assembly and Operating Manual | en | 389555
25
5 Troubleshooting
5.1 Product does not move?
Possible cause
Corrective action
The required air connections are closed
Open the required air connections.
Compressed air lines switched.
Check compressed air lines.
Unused air connections open.
Close unused air connections.
The machine is equipped with a check valve. Use throttle
18].