SCHUNK GKS 16 Assembly And Operating Manual Download Page 3

 
Assembly and Operating Manual 
 
Gripper actuator GMC       
 

 
 

Date printed 23.02.2011 

Safety 

1.1  Symbol Key 

 

You will find this symbol wherever 

hazards for persons

 or 

damage to the product

 

are possible. 
 

 

This symbol indicates 

important information 

on the product or its handling. 

1.2  Appropriate Use 

The unit must only be used within the scope of its technical data. Appropriate use also  
includes compliance with the conditions the manufacturer has specified for commissioning, 
assembly, operation, environment and maintenance. Using the unit with disregard to even a 
minor specification will be deemed inappropriate use. The manufacturer assumes no liability 
for any injury or damage resulting from inappropriate use. 
 
The gripper actuators are manufactured in accordance with the current level of technolog y and 
with recognised safety regulations. During their use, however, there may occur risks to life and 
limb of the user or impairment of the portal actuator and other material assets. 
 
The gripper actuators are intended exclusively for the parallel gripping of service loads in any 
position that do not react in their manipulation with any risk to persons, property or the  
environment. 
 
The maximum permissible service loads and forces are given in our standard catalogue. 
Any usage beyond these definitions is inappropriate. 
The manufacturer cannot be held liable for loss or damage arising therefrom. The risk is borne 
exclusively by the user. 
 
The gripper actuator must only be operated by persons that are  
familiar therewith and that have been instructed in the associated hazards. The relevant acci-
dent prevention regulations and the other generally recognised safety and occupational health 
regulations must be complied with. 

www.comoso.com

Summary of Contents for GKS 16

Page 1: ...tisfaction SCHUNK products are inspiring Our detailed assembly and operation manual will support you Do you have further questions You may contact us at any time even after purchase You can reach us d...

Page 2: ...AL CONDITIONS 5 6 ASSEMBLY AND INSTALLATION 6 6 1 DESIGN PRECAUTIONS 6 6 2 COMPRESSED AIR SUPPLY 6 6 3 SPECIAL CONNECTING MEASURES 6 6 4 ASSEMBLY MEASURES 7 6 5 MEASURES FOR THE INITIAL OPERATION 7 7...

Page 3: ...e current level of technology and with recognised safety regulations During their use however there may occur risks to life and limb of the user or impairment of the portal actuator and other material...

Page 4: ...re in a securely deactivated condition If machine parts must be removed carry out safety precautions as men tioned above Deactivate the compressed air supply to this machine and release any remaining...

Page 5: ...in each case in accordance with Chapter 2 3 General Terms and Conditions The airborne sound emitted from the unit is 70dB A 5 Operating and environmental conditions Do not use the product in environm...

Page 6: ...Ensure that nobody can be placed at risk or be injured when equipment is restarted 6 2 Compressed air supply Use clean compressed air and insert a filter between the supply and the pneumatic system In...

Page 7: ...prevent errors and ensure problem free operation Under no circumstances may gripper actuators be operated with oiled air if they are subsequently to be operated with oil free air Check the technical s...

Page 8: ...ctuator GMC 12 GKS 16 for gripper actuator GMC 16 GKS 20 for gripper actuator GMC 20 GKS 28 for gripper actuator GMC 28 If a gripper actuator including a grip force safety device as described in our s...

Page 9: ...n sets for direct mounting are available for interrogation of end positions Proximity switch complete GMNS The scope of delivery includes 1x retaining plate 1x proximity switch 1x connection cable Fig...

Page 10: ...s to configure a large number of different gripper actuators and gripper indexing actuators The diagram below shows the complete modular set for configuration of parallel gripper actuators GMP and ang...

Page 11: ...omponents may only be replaced by SCHUNK genuine replacement parts Malfunction Cause Remedy Gripper actuator does not open close 1 No compressed air 2 Incorrect pneumatic connections 1 Check compresse...

Page 12: ...air is permissible without restrictions The complete mechanism is already lubricated It is not therefore necessary to lubricate this again before operation Lubrication or relubrication of the mechanis...

Page 13: ...uator GMC 12 GMDI 16 for gripper actuator GMC 16 GMDI 20 for gripper actuator GMC 20 GMDI 28 for gripper actuator GMC 28 In accordance with the section drawing below all other wear parts and individua...

Page 14: ...ne into which the incomplete machine is to be installed with the provisions of the Machinery Directive 2006 42 EC is confirmed Applied harmonized standards especially EN ISO 12100 1 Safety of machines...

Page 15: ...32 Tel 86 21 64433177 Fax 86 21 64431922 info cn schunk com www cn schunk com FRANCE SCHUNK Intec SARL Parc d Activit s des Trois Noyers 15 Avenue James de Rothschild Ferri res en Brie 77614 Marne la...

Page 16: ...unk com www mx schunk com PORTUGAL Sales Representative Victor Marques Tel 34 937 556 020 Fax 34 937 908 692 Mobil 351 963 786 445 info pt schunk com www pt schunk com SPAIN SCHUNK Intec S L Foneria 2...

Reviews: