Start-up
32
01.00 | EGI | Assembly and Operating Manual | en | 1396645
6 Start-up
The product is commissioned via the PLC.
6.1 Preparing commissioning with the web application
Using the web application, prior to integration of the product in
the system (
functions of the product can be tested and status information
displayed. The following functions are possible:
• Execution of movements (home position, inching mode,
positioning, gripping)
• Configuring (limiting stroke, transfer of work settings, reboot)
• Service functions (display of general product information and
errors and saving, downloading the GSDML file)
Starting the web application
Prerequisites
■
An IP address was assigned to the product e. g. by being
registered as a component in the PROFINET network or by
applying the commissioning tool "SIEMENS PRONETA".
Note: In accordance with the PROFINET specifications, the
product will be delivered without an IP address.
■
The product is connected to a 24 V voltage supply.
The motor voltage can be disconnected at any time by an easily
accessible emergency stop switch.
■
The product is connected directly to the Ethernet port of the PC
or in the same network.
■
The product and PC are connected in the same network
(subnet).
Ø
Start browser. Note: The web application is optimized for
Internet Explorer, Firefox, Chrome.