Functional description and operation
16
03.00|SCHUNK IFT Spannkraftmessgerät |en-US
Changing the clamping inserts
The clamping inserts can be changed with the assembly key
supplied. The clamping inserts for the clamping diameters Ø72
mm, Ø96 mm and Ø136 mm are supplied.
1
Measuring head
2
Clamping insert
3
Fastening screw
4
Torx assembly key
WARNING
Imbalance!
Only clamping inserts of the same length may be installed on the
clamping force meter.
The clamping inserts must be arranged symmetrically.
(2 pieces at 180°; 3 pieces at 120°; 6 pieces at 60°)