BEFORE USING YOUR BATTERY CHARGER

It is important to understand the charger’s requirements. This section explains the
charger’s electrical requirements and how to prepare a battery for charging.

PLUGGING IT IN

Your charger requires a 120V AC
receptacle installed according to all local
codes and ordinances.

USING AN EXTENSION CORD

The use of an extension cord is not
recommended. If you must use an

extension cord, please make sure that
you follow these guidelines:

• Make sure that pins on plug of

extension cord are the same number,
size, and shape as those of plug on
charger.

• Check that the extension cord is

properly wired and in good electrical
condition.

• Make sure that the wire size is large

enough for its length and for the AC
ampere rating, as specified in the
chart below.

Length of Cord, in Feet

25

50

100

150

AWG* Size of Cord

18

16

12

10

*AWG=American Wire Gauge

MINIMUM RECOMMENDED EXTENSION CORD

PREPARING YOUR BATTERY TO BE CHARGED

It is important that you read and follow these guidelines while you are preparing to
charge the battery.

• Make sure that you have a 12 volt

lead-acid battery. Determine voltage
of battery by referring to vehicle
owner’s manual. Charge battery
initially at charger’s lowest rate.

• Clean the battery terminals. Be

careful to keep corrosion from getting
in or around your eyes.

• Wear safety glasses. See additional

“Personal Safety Precautions” on
page 4.

• For batteries with removable vent

caps, if required, add distilled water to
each cell until the battery acid
reaches the level recommended by
the manufacturer. This will help purge
excessive gases from the cells. Be
careful not to overfill. If you have a
sealed battery with non-removable
vent caps, no action is necessary.

• Take time to read all of the battery

manufacturer’s specific precautions,
such as removing or not removing
vent caps while charging, and
recommended rates of charge.

• Be sure that the area around the

battery is well ventilated while it is
being charged. Gas can be forcefully
blown away by using a piece of
cardboard or other nonmetallic
material as a fan.

• If it is necessary to remove the battery

from the vehicle to charge it, always
remove the grounded terminal from
the battery first. Turn off all vehicle
accessories to avoid sparks from
occurring.

NOTE: 

A marine (boat) battery

installed in a boat must be removed
and charged on shore.

Summary of Contents for SSC-1000A SpeedCharge

Page 1: ...nd follow them with each use of this product 0099000363 1004 OWNER S MANUAL ELECTRIC CORPORATION Mount Prospect IL 60056 U S A Model SSC 1000A For 12 Volt Batteries Fully Automatic Microprocessor Cont...

Page 2: ...his equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by...

Page 3: ...om the battery being charged as the charger cables will permit Do not expose charger to rain or snow Never charge a frozen battery If battery fluid electrolyte becomes frozen bring battery into a warm...

Page 4: ...resh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes whi...

Page 5: ...ve a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corr...

Page 6: ...ow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconne...

Page 7: ...RY 24 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 5 Plug the power cord into an AC outlet The charger will be set to the Tester Mode for REGULAR battery...

Page 8: ...to be charged to one of the following three SSC 1000A CONTROL PANEL REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and are often marked...

Page 9: ...O 0 Voltage meter activated O 0 0 17 0V 2 Amp charge with battery detected O O xx or xx xV 6 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O O xx or xx xV Charge...

Page 10: ...r the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been changed from tester to charger by sele...

Page 11: ...charge If the charger detects a sulfated battery the charger will switch to a special mode of operation designed for such batteries Activation of the special desulfation mode is indicated by blinking...

Page 12: ...ermocouple This device monitors the temperature and allows the charger to turn the fan on and off as needed If the temperature rises above a preset level the charge current will be reduced to allow th...

Page 13: ...e and eventually reduces the charge rate in a con trolled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode The...

Page 14: ...power than again if necessary the charger can deliver in 24 hours Battery may also be faulty The green CHARGED light The battery may be fully If the battery is in a vehicle turns on a few minutes afte...

Page 15: ...15 NOTES...