Schumacher SPI 16 PRO Instruction Manual Download Page 3

 

2. 

Connect the output conductor with red clamps to the positive (+) pole of the battery. 

3. 

Connect the output conductor with black clamps to the negative (-) pole of the battery. 

4. 

Caution:

 ensure that both clamps have adequate contact with the battery terminals. 

 
HOW TO USE THE BATTERY CHARGER 
 

1. 

Once  the  output  clamps  have  been  connected  to  the  battery,  connect  the  power  cord  to  the 
mains socket, making sure that the voltage corresponds to the rated voltage of the charger. 

 
2. 

With  the  charger  in  “stand-by”  mode,  set  the  appropriate  charge  parameters  using  the  mode 
button to select the correct voltage.  

 
For 

12V batteries

 the following charging parameters can be selected 

via the “Function" button: 

 4A

 

 

For charging 12V 5Ah to 80Ah batteries 
Maintenance for 12V 5Ah to 120Ah batteries 
Suitable for charging WET and Gel batteries

 

 8A

 

 

For charging 12V 50Ah to 160Ah batteries 
Maintenance for 12V 50Ah to 250Ah batteries 
Suitable for charging WET and Gel batteries

 

16A

 

 

For charging 12V 90Ah to 360Ah batteries 
Maintenance for 12V 90ah to 550Ah batteries 
Suitable for charging WET and Gel batteries

 

 4A

 

 

For charging 12V 5Ah to 80Ah batteries  
Maintenance for 12V 5Ah to 120Ah batteries 
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB or WET batteries 
with temperatures below 5C° 

 8A

 

 

For charging 12V 50Ah to 160Ah batteries 
Maintenance for 12V 50Ah to 250Ah batteries 
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB or WET batteries 
with temperatures below 5C° 

16A

 

 

For charging 12V 90Ah to 360Ah batteries 
Maintenance for 12V 90ah to 550Ah batteries 
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB or WET batteries 
with temperatures below 5C° 

 4A

 

 

For charging 12V 5Ah to 80Ah batteries 
Maintenance for 12V 5Ah to 120Ah batteries 
Suitable for charging lithium batteries

: LiFePO4

 (do not charge other types of lithium 

batteries) 

 8A

 

 

For charging 12V 50Ah to 160Ah batteries 
Maintenance for 12V 50Ah to 250Ah batteries 
Suitable for charging lithium batteries: LiFePO4 (do not charge other types of lithium 
batteries) 

16A

 

 

For charging 12V 90Ah to 360Ah batteries 
Maintenance for 12V 90ah to 550Ah batteries 
Suitable for charging lithium batteries: LiFePO4 (do not charge other types of lithium 
batteries) 

 

Lithium batteries are equipped with a BMS that in some cases can prevent the start of the 
charging cycle; in this scenario to activate the charge process Press and hold the 
“Function" button for 5 seconds, after setting the charger in lithium mode. 

 

4A-8A-16A 
AGM

 

The 

RECONDITION

 mode is for WET and AGM batteries that have long been inactive and have an 

acid stratification. 

Caution:

 due to the high voltage that is reached during this charging cycle, 

recovery must be carried out with battery removed from the vehicle. A battery recovery connected to 
the vehicle could cause damage to the on-board electronics. (Only in 12V mode)

 

 
After selecting the appropriate 12volt function the charging process starts automatically after 5 seconds. 
 

Summary of Contents for SPI 16 PRO

Page 1: ...Only with charger set on RECON constant current deep charge phase and increasing voltage to increase battery charging capacity Diagnosis of battery status A2 The charger analyzes the state of efficie...

Page 2: ...the electronic circuit inside the device will void the warranty In case of damage the power cord of the appliance must be replaced by authorized technicians since intervention requires the use of spec...

Page 3: ...for charging AGM START STOP and AGM SPIRAL and EFB or WET batteries with temperatures below 5C 16A For charging 12V 90Ah to 360Ah batteries Maintenance for 12V 90ah to 550Ah batteries Suitable for cha...

Page 4: ...this function This function allows you to keep the memory of a vehicle active during battery changes or in all cases where the battery is disconnected from the vehicle circuit Only in Mode 12V Warnin...

Page 5: ...he battery is unable to absorb current The battery may be defective Consult the nearest Battery Service Center Battery recovery failed after a full cycle of desulfation The battery may be defective Co...

Page 6: ...pecifications given by the Manufacturer insufficient care repairs carried out by persons or entities or with parts not approved by Manufacturer poor care accidents unauthorized changes or modification...

Page 7: ...ion Centers Schumacher Europe Office in Belgium Rue de la Baronnerie 3 B 4920 Harz Belgium 32 4 388 20 17 info ceteor com Schumacher Asia Pacific Office in Australia 29 51 Wayne Goss Drive Berrinba Qu...

Reviews: