Schumacher SpeedCharge 6000A Owner'S Manual Download Page 12

12

while waiting and will reset if the
engine is not cranked within 10
minutes. (If the charger resets, it sets
itself for a 2A charge and REGULAR
battery.)

 

While waiting for cranking,

the digital display shows the battery
voltage (it can’t be set to percent).

2.

Cranking 

 -  When cranking is

detected, the SpeedCharge will
automatically deliver up to its
maximum output (at least 60A) as
required by the starting system for up
to 8 seconds or until the engine
cranking stops. The digital display
shows a countdown of the remaining
crank time in seconds. It starts at 8
and counts down to 0.

3.

Cool Down

 - After cranking, the unit

enters a mandatory 2-minute (120
second) cool down state. During this
period, no settings can be changed.
The buttons are ignored. The digital

display indicates the remaining cool
down time in seconds. It starts at 120
and counts down to 0. The 60A
START LED blinks once every
second.

 

During the cool down period,

the charger delivers charge at a rate
of 10A and the CHARGING LED is
lit. After 2 minutes, the 60A START
LED will stop blinking and will light
continuously, indicating that another
crank cycle can be started. The
digital LED will change from display-
ing the countdown back to displaying
the battery voltage.

ENGINE STARTING NOTES:

• When the 60A START rate has been

selected, the battery type selected
does not matter and no battery type
LED will be lit.

• If the battery is disconnected during

the cool down period, the charger will
reset.

USING YOUR BATTERY CHARGER

OVERVIEW

Using the SpeedCharge battery charger
is very simple. First, connect the battery
and AC power following the precautions
listed under “OPERATING INSTRUC-
TIONS”. Then select the appropriate
BATTERY TYPE and CHARGE RATE
for your battery. The SpeedCharge will
then do everything automatically. This
section explains a few details.

CHARGING: 

If the charger does not

detect a properly connected battery, the
CHECK (red) LED will light continuously
until such a battery is detected. Charg-
ing will not begin while the CHECK light
is on. When charging begins, the
CHARGING LED will be lit.

AUTOMATIC SHUT OFF:

 When the 2A

or 30A

10A charge rate is selected,

the charger is set to perform an auto-
matic charge. When an automatic
charge is performed, the charger stops
charging automatically after the battery
is charged.

ABORTED CHARGE: 

If charging can’t

be completed normally, charging will be
aborted. When charging is aborted, the
charger’s output is shut off and the red
CHECK LED and digital LED blink on
and off (at opposite times). In that state,
the SpeedCharge ignores all buttons. To
reset from after an aborted charge,
either disconnect the battery or unplug
the charger.

DESULFATION MODE:

 If a battery is

left discharged for an extended period, it
could become sulfated and not accept a
normal charge. If the charger detects a
sulfated battery, the charger will switch
to a special mode of operation designed
for such batteries. Activation of the spe-
cial desulfation mode is indicated by
blinking the CHARGING LED. If suc-
cessful, normal charging will resume af-
ter the battery is desulfated. The
CHARGING LED will then stop blinking
and light continuously. Desulfation could
take up to 10 hours. If desulfation fails,
charging will be aborted and the CHECK
(red) LED will blink.

Summary of Contents for SpeedCharge 6000A

Page 1: ...99000399 0104 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model 6000A For 12 Volt Batteries SpeedCharge computer smart 30a m p R A P I D C H A R G E 60a m p E N G I N...

Page 2: ...nt does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or mor...

Page 3: ...TE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY To reduc...

Page 4: ...ave plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touchin...

Page 5: ...e a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be care ful to keep corr...

Page 6: ...s the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before att...

Page 7: ...4 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 7 To disconnect the Charger unplug its power cord before attempting to disconnect the charger clamps Then...

Page 8: ...an engine with a weak or 6000A CONTROL PANEL run down battery Always use in combination with a battery BATTERY TYPE SWITCH Use this switch button to set the type of battery to be charged to one of the...

Page 9: ...nator O O 0 199 2 Amp charge with battery detected O O xx or xx xV 10 Amp charge with battery detected O YEL xx or xx xV 30 Amp charge activated O ORG xx or xx xV Charge complete Maintain Mode started...

Page 10: ...n minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTINGAFTERCHARGING After the unit has been changed from tester to cha...

Page 11: ...HARGING yellow LED does not light in the alternator test mode The CHECK red LED lights if the voltage is much higher or lower than normally desired When the tester display mode is set to voltage none...

Page 12: ...harger is very simple First connect the battery and AC power following the precautions listed under OPERATING INSTRUC TIONS Then select the appropriate BATTERY TYPE and CHARGE RATE for your battery Th...

Page 13: ...charging has started by pressing the CHARGE RATE or BATTERY TYPE button the charging process will be restarted The voltage displayed during charging is the charging voltage and usually will be higher...

Page 14: ...d eventually reduces the charge rate in a controlled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There ar...

Page 15: ...k of battery clip Select the batteries requiring more desired charge rate and power than a 30 10 Amp battery type again if charger can deliver within necessary 24 hours The battery may also be faulty...

Page 16: ...turer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages...

Reviews: