Schumacher SpeedCharge 1200A Owner'S Manual Download Page 4

4

Never

 place charger directly above

battery being charged. The gases from
the battery will corrode and damage the
charger.

Never 

touch the battery clamps together

when the charger is on. You could
cause a spark.

Never 

operate charger if it has received

a hard blow, been dropped, or otherwise
damaged. Take it to a qualified profes-
sional for inspection and repair.

Be sure

 to position the charger power

cord to prevent it from being stepped
on, tripped over, or damaged.

Never

 pull out the plug by the cord

when unplugging the charger. Pulling on
the cord may cause damage to the cord
or the plug.

Do not

 operate the charger if it has a

damaged power cord or plug. Have the
cord replaced.

PERSONAL SAFETY PRECAUTIONS

Wear complete eye and clothing
protection 

when working with lead-

acid batteries.

Make sure 

that someone is within

range of your voice to come to your
aid if needed while you work with or
are near a lead-acid battery.

Have plenty of fresh water and
soap 

nearby for use in case battery

acid contacts your eyes, skin, or
clothing. If this happens, wash
immediately with soap and water.
Then get medical attention.

Avoid touching your eyes 

while

working with a battery. Acid particles
(corrosion) may get into your eyes. If
this occurs, flush eyes immediately
with running cold water for at least 10
minutes. Then immediately get
medical attention.

Never

 charge a frozen battery.

Remove all personal metal items

from your body such as rings,
bracelets, necklaces and watches,
while working with a lead-acid battery.
A battery can produce a short circuit
current high enough to weld a ring (or
the like) to metal, causing a severe
burn.

Take care 

not to drop any metal tool

or metal object onto the battery. This
may result in a spark or short circuit
across the battery or another electri-
cal device that may cause an explo-
sion.

Always 

operate the battery charger in

an open, well-ventilated area.

Never 

smoke or allow a spark or

flame in the vicinity of the battery or
engine. Batteries generate explosive
gases.

Neutralize 

any acid spills thoroughly

with baking soda before attempting to
clean up.

Summary of Contents for SpeedCharge 1200A

Page 1: ... U S A Model 1200A For 12 Volt Batteries SpeedCharge computer smart 8 12a m p F A S T C H A R G E a m p M E D I U M C H A R G E a m p S L O W C H A R G E 2 Fully Automatic Microprocessor Controlled Battery Charger with Battery Tester Send Warranty Product Repairs to Customer Service Returns P O Box 280 1025 E Thompson Hoopeston IL 60942 0280 Questions Call Customer Service 1 800 621 5485 ...

Page 2: ...is equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different ...

Page 3: ...m the battery being charged as the charger cables will permit Do not expose charger to rain or snow Never charge a frozen battery If battery fluid electrolyte becomes frozen bring battery into a warm area to allow battery to thaw before you begin charging Never allow battery acid to drip on charger when reading specific gravity or filling battery Never set a battery on top of charger WARNING Handl...

Page 4: ...fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes while working with a battery Acid particles corrosion may get into your eyes If this occurs flush eyes immediately with running cold water for at least 10 minutes Then immediately get medical attention ...

Page 5: ...ave a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corrosion from getting in or around your eyes Wear safety glasses See additional Personal Safety Precautions on page 4 For batteries with removable vent caps if required add distilled water to each cell ...

Page 6: ...low LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconnect the output clamps Then standing away from the battery remove the output clamp from the chassis or engine block Finally remove the output clamp from the battery post 9 Clean and store the charger i...

Page 7: ...ERY 24 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 5 Plug the power cord into an AC outlet The charger will be set to the Tester Mode for REGULAR battery type 6 Press the appropriate control buttons to select the desired charge rate and battery type The CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on ...

Page 8: ...o be charged to one of the following three 1200A CONTROL PANEL REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent caps and are often marked low maintenance or maintenance free DEEP CYCLE Deep cycle batteries are usually marked as deep cycle or marine Deep cycle batteries are usually larger than the other types AGM GEL CELL AGM and gel cell bat...

Page 9: ...th no battery O O 0 Voltage meter activated O 0 0 17 0V 2 Amp charge with battery detected O O xx or xx xV 8 Amp charge with battery detected O O xx or xx xV 12 Amp charge with battery detected O O xx or xx xV Charge complete Maintain Mode started O 100 or xx xV Desulfation mode activated B 15 or 16V Charge aborted B 18 8 B User selected User sel User sel User selected User selected User selected ...

Page 10: ...ter the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been changed from tester to charger by selecting a charge rate it remains a charger as long as it has power Disconnect and reconnect the power to change the unit back to a tester TESTER STATUS LEDs When the charger is operating as a battery ...

Page 11: ...l charge If the charger detects a sulfated battery the charger will switch to a special mode of operation designed for such batteries Activation of the special desulfation mode is indicated by blinking the CHARGING LED If successful normal charging will resume after the battery is desulfated The CHARGING LED will then stop blinking and light continuously Desulfation could take up to 10 hours If de...

Page 12: ...hermocouple This device monitors the temperature and allows the charger to turn the fan on and off as needed If the temperature rises above a preset level the charge current will be reduced to allow the charger to cool If the tem perature can not be reduced at the lower charge rate the charge current will be turned off until the temperature is reduced to a normal level The charger will then contin...

Page 13: ...te and eventually reduces the charge rate in a con trolled manner After the charging process has started the digital display can be used to determine charging progress by selecting the BATTERY mode There are some important facts to keep in mind when charging a battery When the display indicates 77 charged the battery has been charged enough to start most vehicles and has already been charged as mu...

Page 14: ... power than again if necessary the charger can deliver in 24 hours Battery may also be faulty The green CHARGED light The battery may be fully If the battery is in a vehicle turns on a few minutes after charged or recently charged turn the headlights on for a connecting to the battery leaving the battery voltage few minutes to reduce the high enough to appear to be battery voltage and try fully ch...

Page 15: ...15 NOTES ...

Page 16: ...anufacturer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WA...