Never

 set a battery on top of charger.

Never

 place charger directly above

battery being charged. The gases from
the battery will corrode and damage the
charger.

Never 

touch the battery clamps together

when the charger is on. You could
cause a spark.

Never 

operate charger if it has received

a hard blow, been dropped, or otherwise
damaged. Take it to a qualified profes-
sional for inspection and repair.

Be sure

 to position the charger power

cord to prevent it from being stepped
on, tripped over, or damaged.

Never

 pull out the plug by the cord

when unplugging the charger. Pulling on
the cord may cause damage to the cord
or the plug.

Do not

 operate the charger if it has a

damaged power cord or plug. Have the
cord replaced.

PERSONAL SAFETY PRECAUTIONS

Wear complete eye and clothing
protection 

when working with lead-

acid batteries.

Make sure 

that someone is within

range of your voice to come to your
aid if needed while you work with or
are near a lead-acid battery.

Have plenty of fresh water and
soap 

nearby for use in case battery

acid contacts your eyes, skin, or
clothing. If this happens, wash
immediately with soap and water.
Then get medical attention.

Avoid touching your eyes 

while

working with a battery. Acid particles
(corrosion) may get into your eyes. If
this occurs, flush eyes immediately
with running cold water for at least 10
minutes. Then immediately get
medical attention.

Never

 charge a frozen battery.

Remove all personal metal items

from your body such as rings,
bracelets, necklaces and watches,
while working with a lead-acid battery.
A battery can produce a short circuit
current high enough to weld a ring (or
the like) to metal, causing a severe
burn.

Take care 

not to drop any metal tool

or metal object onto the battery. This
may result in a spark or short circuit
across the battery or another electri-
cal device that may cause an explo-
sion.

Always 

operate the battery charger in

an open, well-ventilated area.

Never 

smoke or allow a spark or

flame in the vicinity of the battery or
engine. Batteries generate explosive
gases.

Neutralize 

any acid spills thoroughly

with baking soda before attempting to
clean up.

Summary of Contents for SpeedCharge 1000AP

Page 1: ...product 0099000479 0105 SpeedCharge computer smart 6 10a m p F A S T C H A R G E a m p M E D I U M C H A R G E a m p S L O W C H A R G E 2 Fully Automatic Microprocessor Controlled Battery Charger ELECTRIC CORPORATION Mount Prospect IL 60056 U S A OWNER S MANUAL Model 1000AP For 12 Volt Batteries ...

Page 2: ... not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equ...

Page 3: ...er as far away from the battery being charged as the charger cables will permit Do not expose charger to rain or snow Never charge a frozen battery If battery fluid electrolyte becomes frozen bring battery into a warm area to allow the battery to thaw before you begin charging Never allow battery acid to drip on charger when reading specific gravity or filling battery WARNING Handling the cord on ...

Page 4: ...ery Have plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching your eyes while working with a battery Acid particles corrosion may get into your eyes If this occurs flush eyes immediately with running cold water for at least 10 minutes Then immediately get...

Page 5: ...ave a 12 volt lead acid battery Determine voltage of battery by referring to vehicle owner s manual Charge battery initially at charger s lowest rate Clean the battery terminals Be careful to keep corrosion from getting in or around your eyes Wear safety glasses See additional Personal Safety Precautions on page 4 For batteries with removable vent caps if required add distilled water to each cell ...

Page 6: ... LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the charger unplug its power cord before attempting to disconnect the output clamps Then standing away from the battery remove the output clamp from the chassis or engine block Finally remove the output clamp from the battery post 9 Clean and store the charger in a...

Page 7: ... BATTERY 24 6 GAUGE CABLE POWER CORD TO GROUNDED POWER OUTLET CHARGING BATTERY REMOVED FROM THE VEHICLE 5 Plug power cord into an AC outlet The charger will be set to the 2 Amp for REGULAR battery type 6 Press the appropriate control buttons to select the desired charge rate and battery type The CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check...

Page 8: ...rine Deep cycle batteries are usually larger than the other types AGM GEL CELL AGM and gel cell batteries have sealed cases without vent caps Such batteries are often smaller than the other types 6A or 10A CHARGE RATE Use for charging automotive batteries marine batteries and deep cycle batteries Not intended for industrial applica tions With the exception of AGM and gel cell batteries all other b...

Page 9: ...nnect the battery or unplug the charger DESULFATION MODE If a battery is left discharged for an extended period it could become sulfated and not accept a normal charge If the charger detects a sulfated battery the charger will switch to a special mode of operation designed for such batteries Activation of the special desulfation mode is indicated by blinking the CHARGING LED If successful normal c...

Page 10: ...the charging process depends on three factors 1 Battery State If a battery has only been slightly discharged it can be charged in less than a few hours The same battery could take up to 10 hours if very weak 2 Battery rating A higher rated battery will take longer to charge than a lower rated battery under the same conditions A battery is rated in ampere hours AH reserve capacity RC and cold crank...

Page 11: ...g Battery may be bad Charger The CHECK red light This will happen if the Reset the charger by un always flashes before the battery did not reach full plugging it or briefly discon battery is completely charge within 24 hours May necting the negative battery charged be due to a very large clip Select the desired battery or a bank of batteries charge rate and battery type requiring more power than a...

Page 12: ...anufacturer or its authorized representative The manufacturer makes no warranty other than this limited warranty and expressly excludes any implied warranty including any warranty for consequential damages THIS IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WA...

Reviews: