Schumacher SCI10 Owner'S Manual Download Page 5

‡

 

5

 

‡

7.

GROUNDING AND AC POWER CORD CONNECTIONS

WARNING

RISK OF ELECTRIC SHOCK OR FIRE.

7.1 

This battery charger is for use on a nominal 230V, 50 Hz circuit. (See the warning 

label on the charger for the correct input voltage.) The plug must be plugged into 

an outlet that is properly installed and grounded in accordance with all local codes 

and ordinances. The plug pins must 

¿

t the receptacle (outlet). Do not use with an 

ungrounded system.

7.2 

DANGER

 

Never alter the AC cord or plug provided – if it does not 

¿

t the outlet, have 

a proper grounded outlet installed by a quali

¿

ed electrician. An improper connection can 

result in a risk of an electric shock or electrocution. 

7.3 

Recommended minimum AWG size for extension cord:

‡

 100 feet (30.5 meters) long or less – use a 16 gauge (1.31 mm

2

) extension cord.

‡

 Over 100 feet (30.5 meters) long – use a 14 gauge (2.08 mm

2

) extension cord.

8.

CONTROL 

PANEL

1.

Charge Rate Button

2.

AC Power

3.

Connected LED

4.

Battery Type/Mode Button

5.

Charging LED

6.

Charged LED

4

1

2

3

5

6

NOTE: 

See the Operating Instructions section for a complete description of the  

charger modes.

Charge Rate Button 

Use this button to set the maximum charge rate. Press the button until the desired 

charge rate is selected.

– Charges and maintains small batteries. Maintains large batteries.

– Charges small batteries, such as those commonly used in garden tractors,

snowmobiles and motorcycles. Not for charging large batteries.

– Charges automotive, marine and light truck batteries.

NOTE: 

Once the charger has started charging the battery; if you press the Charge 

Rate button once, the output current is shut off. If you press the Charge Rate button 

again, the current will go back on at the same setting it was when it was turned off. For 

example: The charger is charging a battery at the fast charge rate setting. If you press 

the Charge Rate button, the output is turned off. If you press the Charge Rate button 

again, the output will turn back on at the fast charge rate setting. 

Battery Type/Mode Button 

Set the type of battery to be charged, or Desulfation Mode:

 

(Calcium) – Calcium batteries are acid batteries impregnated with calcium. 

 

(Absorbed Glass Mat/Gel) – AGM batteries have electrolyte absorbed in 

separators consisting of a sponge-like mass of matted glass 

¿

ber. Gel batteries contain 

gelled electrolytes. These batteries are sealed with valves and should not be opened.

 

(Desulfation Mode) – A special mode of operation designed for sulfated batteries.

NOTE: 

When charging a battery that is not marked, check the manual of the item which 

uses the battery for the correct battery type. Make sure the battery complies with the 

safety instructions in Section 2.3.

Summary of Contents for SCI10

Page 1: ...0099001262WB 02 SCI10 English Page 02...

Page 2: ...if not avoided could result in damage to the equipment vehicle or property WARNING RISK OF ELECTRIC SHOCK OR FIRE 1 1 To reduce the risk of damage to the electric plug or cord pull by the plug rather...

Page 3: ...attery acid contacts your skin or clothing immediately wash the area with soap and water If acid enters your eye immediately ood the eye with cold running water for at least 10 minutes and get medical...

Page 4: ...he frame or engine block 5 6 For a positive grounded vehicle connect the NEGATIVE BLACK clip from the battery charger to the NEGATIVE NEG N ungrounded post of the battery Connect the POSITIVE RED clip...

Page 5: ...rges and maintains small batteries Maintains large batteries Charges small batteries such as those commonly used in garden tractors snowmobiles and motorcycles Not for charging large batteries Charges...

Page 6: ...n using this mode or damage to the car s electrical system may result If the battery is left discharged for an extended period of time it could become sulfated and not accept normal charge If you sele...

Page 7: ...charger Failure to do so could result in personal injury or property damage 12 SPECIFICATIONS Input 230V 50 Hz 1 8 A Output 6 12V 2A 6A 10A Weight 1 12 kg Reverse Polarity Protection Yes Operating Te...

Page 8: ...including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of tness for a particular purpose Further...

Page 9: ...ch the CE marking was af xed is 2013 Manufacturer John Waldron President January 7 2013 Hereby declares that the equipment Model SCI10 is compliant to the DIRECTIVE 2002 95 EC RoHS Directive as well a...

Reviews: