Schumacher SCF-10000A SpeedCharge Owner'S Manual Download Page 11

11

OVERVIEW

The 10000A has an engine start function
that can be used to jump start your
vehicle if the battery is low by providing
100 amps of current to assist engine
cranking.

STARTING SEQUENCE

There are a few basic steps involved
when using the engine start function.

1. Connect the charger battery clamps

to the battery or charging system.  Be
sure to follow all of the precautions
listed under “OPERATING INSTRUC-
TIONS”.

2. Connect the charger power cord to a

120 VAC outlet. Again, be sure to
follow all of the precautions listed
under “OPERATING INSTRUC-
TIONS”.

3. Press the CHARGE RATE button

until the 100A START indicator is lit.

4. Crank the engine until it starts or 5

seconds passes.

5. If the engine did not start, wait for the

charger to cool then repeat step 4.

During the starting sequence listed
above, the charger is set to one of three
states.

1.

Wait for cranking

 - The charger

waits until the engine is actually
being cranked before delivering 100
amps for engine start. The charger
delivers charge at a rate of 20 amps
while waiting and will reset if the
engine is not cranked within 5
minutes. (If the charger resets, it sets
itself for a 2A charge and 12V
REGULAR battery.)

 

While waiting for

cranking, the digital display shows
the battery voltage (it can’t be set to
percent).

USING YOUR ENGINE STARTER

2.

Cranking 

- When cranking is

detected, the charger will automati-
cally deliver up to its maximum
output (at least 100A) as required by
the starting system for up to 5
seconds or until the engine cranking
stops. The digital display shows a
countdown of the remaining crank
time in seconds. It starts at 5 and
counts down to 0.

3.

Cool Down

 - After cranking, the unit

enters a mandatory 2-minute (120
second) cool down state. During this
period, no settings can be changed.
The buttons are ignored. The digital
display indicates the remaining cool
down time in seconds. It starts at 120
and counts down to 0. The 100A
START LED blinks once every
second.

 

During the cool down period,

the charger delivers charge at a rate
of 20A and the CHARGING LED is
lit. After 2 minutes, the 100A START
LED will stop blinking and will light
continuously, indicating that another
crank cycle can be started. The
digital LED will change from display-
ing the countdown back to displaying
the battery voltage.

ENGINE STARTING NOTES:

• If the battery is disconnected during

the cool down period, the charger will
reset.

Summary of Contents for SCF-10000A SpeedCharge

Page 1: ...ctions and follow them with each use of this product 0099000450 0605 OWNER S MANUAL Schumacher Electric Corporation Mount Prospect IL 60056 U S A Model SCF 10000A For 6 and 12 Volt Batteries Send Warr...

Page 2: ...rticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment on and off the user is encouraged to try to co...

Page 3: ...RATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING YOUR CHARGER YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY SAVE T...

Page 4: ...plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash immediately with soap and water Then get medical attention Avoid touching yo...

Page 5: ...ne voltage of battery by referring to vehicle owner s manual or the battery markings Be sure to set the charger to the 6V or 12V mode accordingly Charge battery initially at charger s lowest rate Clea...

Page 6: ...ds the CHARGING yellow LED should light and the charging process should start If the CHECK red LED is on check for correct cable connections 8 To disconnect the Charger unplug its power cord before at...

Page 7: ...cord before attempting to disconnect the charger clamps Then standing away from the battery remove the output clamp from the CHARGING BATTERY REMOVED FROM THE VEHICLE NEGATIVE battery post Finally rem...

Page 8: ...to set the type of battery to be charged to one of the following SCF 10000A CONTROL PANEL 12V REGULAR This is the type of battery usually used in cars trucks and motorcycles These batteries have vent...

Page 9: ...r activated O 0 0 17 0V 2 Amp charge with battery detected O O xx or xx xV 15 Amp charge activated O O xx or xx xV 40 Amp charge activated O O xx or xx xV Charge complete Maintain Mode started O 100 o...

Page 10: ...ed within the first ten minutes after the unit is powered up the unit will remain a tester not a charger indefinitely unless a charge rate is selected TESTING AFTER CHARGING After the unit has been ch...

Page 11: ...5 minutes If the charger resets it sets itself for a 2A charge and 12V REGULAR battery While waiting for cranking the digital display shows the battery voltage it can t be set to percent USING YOUR EN...

Page 12: ...signed for such batteries Activation of the spe cial desulfation mode is indicated by blinking the CHARGING LED If suc cessful normal charging will resume af ter the battery is desulfated The CHARGING...

Page 13: ...at period If the vehicle will only be operated for a short period short drive the battery might need to be charged again before it could start the vehicle again Reviving your battery If you only wish...

Page 14: ...if it is determined that the battery can accept the higher rate All charging modes will decrease the charge rate as the battery approaches maximum charge After the charging process has started the di...

Page 15: ...nnecting the negative large battery or a bank of battery clip Select the batteries requiring more desired charge rate and power than a 40 15 Amp battery type again if charger can deliver within necess...

Page 16: ...ANUFACTURER NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS EXPRESS LIMITED WARRANTY THE MANUFACTURER MAKES NO WARRANTY OF MERCHANTABIL...

Page 17: ...e dispositif et les observer chaque emploi 0099000450 0605 Manuel d utilisation Schumacher Electric Corporation Mount Prospect IL 60056 U S A Faire parvenir les produits r parer sous garantie Customer...

Page 18: ...dans un type d installation sp cifique Si cet appareil cause effectivement une interf rence nuisible la r ception de la radio ou de la t l vision ce qui peut tre v rifi en allumant et en teignant l ap...

Page 19: ...er avant de la recharger Ne laissez jamais d acide de batterie d goutter sur le chargeur lorsque vous MISE EN GARDE la manipulation du cordon de cet appareil ou du cordon des accessoires vendus avec c...

Page 20: ...mb acide ou proximit de celle ci Ayez toujours une source d eau fra che et de savon proximit en cas d claboussure d acide dans les yeux sur la peau ou les v tements Le cas ch ant rincezimm diatementla...

Page 21: ...tteriepourconna tre le voltage de celle ci Assurez vous de r gler le chargeur au mode 6 V ou 12 V selon le voltage de la batterie La premi re fois chargez la batterie au taux de charge le plus bas Net...

Page 22: ...uessecondespour indiquer le d but du cycle de charge Si le voyant rouge V rifier s allume v rifiez vos branchements 8 Pour arr ter le chargeur d branchez D ABORDlecordondelaprise Ensuite en vous tenan...

Page 23: ...e au c ble N GATIF et finalement la pince fix e la borne POSITIVE de la batterie 8 Nettoyez le chargeur et rangez le dans un endroit sec CIRCUIT DE D MARRAGE D URGENCE Ce chargeur de batterie peut au...

Page 24: ...et por tent souvent les inscriptions Faible entretien Low Maintenance ou Sans entretien Main tenance free D CHARGE POUSS E 12 V les batteries d chargepouss eportentg n ralementlamen tion D charge pou...

Page 25: ...terie A A 0 Voltm tre activ A 0 0 17 0 Charge de 2 A avec batterie d tect e A A xx ou xx x V Charge de 15 A activ e A A xx ou xx x V Charge de 40 A activ e A A xx ou xx x V Charge compl te Mode de mai...

Page 26: ...ch e au chargeur Dans ce cas le chargeur reviendra aux valeurs par d faut de 2 Apour une batterie Ordinaire 12 V TESTEUR SANS LIMITE DE TEMPS Si vous appuyez sur le bouton Mode d affichage ou le bouto...

Page 27: ...ge de surface en cr ant une demande temporaire sur la batterie du v hicule comme allumer les phares ou d autres accessoires Le pourcentage est mesur de 0 100 Le testeur de batterie est con u pour test...

Page 28: ...ans les 5 minutes Lorsque le chargeur se r initialise il revient aux valeurs par d faut de 2 A pour une batterie Ordinaire 12 V Pendant l attente l affichage indiquera le voltage de la batterie on ne...

Page 29: ...ation peut durer jusqu 10 heures Si la d sulfuration ne peut tre effectu e le voyant rouge V rifier se mettra clignoter FIN DU CYCLE DE CHARGE la fin du cycle de charge le voyant vert Charg e s allume...

Page 30: ...au sujet de la charge d une batterie Lorsque l affichage montre un pourcentage de charge de 77 la batterie est suffisamment charg e pour faire d marrer la plupart des v hicules Lorsque l affichage mo...

Page 31: ...s de puissance de charge que 40 15 A en 24 heures La batterie pourrait aussi tre d fectueuse R initialisez le chargeur en le d branchant et le rebranchant ou en d branchant bri vement la pince fix e a...

Page 32: ...pay s au fabricant ou l un de ses repr sentants agr s Cette garantie est nulle si le produit est l objet d un usage impropre s il est manipul avec n gligence ou s il est r par ailleurs que chez le fab...

Reviews: