![Schumacher PS-2352 Instruction Manual Download Page 10](http://html1.mh-extra.com/html/schumacher/ps-2352/ps-2352_instruction-manual_1215057010.webp)
10
If a problem does occur, check the following:
PROBLEM
POSSIBLE CAUSE
SOLUTION
No Meter Reading
Clips are not making
Rock clips back and forth for a better
(AC Cord Unplugged)
a good connection.
connection.
Battery voltage is too low.
Plug AC line into outlet.
Meter should now indicate.
2 amp charge rate being used.
None, meter will not indicate here.
Charger will not turn
AC outlet is dead.
Plug in a lamp to check for voltage.
on when properly connected.
Poor electrical connection.
Check connections, rock back and forth
for a better connection.
Clicking noise from charger.
Circuit breaker is cycling.
May be in the wrong switch position
Battery is defective.
Have Battery checked.
Severely discharged battery
Allow charging to continue until battery has a
but otherwise a good battery.
chance to recover sufficiently to take a charge.
If more than 20 min. stop charging and have
the battery checked.
Reverse connections at battery.
Shut off charger and correct lead connections.