background image

 

10

 

Troubleshooting

PROBLEM

POSSIBLE CAUSE

REASON

Battery clamps do not 

spark when touched 

together.

The charger is equipped 

with an auto-start feature. 

It will not supply current to 

the battery clamps until a 

battery is properly connected. 

The clamps will not spark if 

touched together.

No problem; this is a normal 

condition.

The charger will not 

turn on when properly 

connected.

AC outlet is dead.

Poor electrical connection.

Check for open fuse or circuit 

breaker supplying AC outlet.

Check power cord and extension 

cord for loose fitting plug.

Engine start does  

not work. 

Drawing more than 85 amps.

Failure to wait 3 minutes (180 

seconds) between cranks.

The charger may be 

overheated. 

Battery may be severely 

discharged. 

Crank time varies with the amount 

of current drawn. If cranking draws 

more than 85 amps, crank time 

may be less than 5 seconds.

When the countdown from 180 to 

0 is displayed, wait until the display 

shows “

rdy

” for the next crank.

The thermal protector may have 

tripped and needs a little longer 

to reset. Make sure the charger 

vents are not blocked. Wait and try 

again.

On a severely discharged battery, 

use the 30A Boost rate for 10 to 15 

minutes, to help assist in cranking.

I cannot select a 6V or 

12V setting.

The charger is equipped 

with Auto Voltage Detection, 

which automatically detects 

the voltage and charges the 

battery.

No problem; this is normal.

I press the display 

button, but do not 

see the percentage of 

charge.

When first connected to a 

battery, the display shows 

voltage only.

This is normal. The percentage 

of charge is only displayed during 

charging.

The display shows  

bAD

 / 

bAt

 / 

F01

”.

The battery voltage is still 

below 10V (for a 12V battery) 

or 5V (for a 6V battery) after 2 

hours of charging.

The battery may be defective. Make 

sure there are no loads on the 

battery. If there are, remove them. 

If there are none, have the battery 

checked or replaced. 

The display shows  

bAD

 / 

bAt

 / 

F02

”.

Desulfation was unsuccessful, 

after 10 hours.

The battery may be defective. Have 

battery checked or replaced.

The display shows  

bAD

 / 

bAt

 / 

F05

”.

Lack of progress is detected 

after 12 hours in Maintain mode.

 

The battery won’t hold a charge. 

May be caused by a drain on the 

battery or the battery could be bad. 

Make sure there are no loads on the 

battery. If there are remove them. 

If there are none, have the battery 

checked or replaced.

Summary of Contents for SC1307

Page 1: ...instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el cargador de bater a de manera segura y confiable...

Page 2: ...11 LIMITED WARRANTY 11 WARRANTY CARD 23 CONTENIDOS INSTRUCCIONES IMPORTANTES DE SEGURIDAD 12 PRECAUCIONES DE SEGURIDAD PERSONAL 12 PREPARACI N PARA LA CARGA 13 UBICACI N DEL CARGADOR 13 PRECAUCIONES...

Page 3: ...TRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use...

Page 4: ...position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS I...

Page 5: ...States is not recommended and should not be used 8 3 USING AN EXTENSION CORD The use of an extension cord is not recommended If you must use an extension cord follow these guidelines Pins on plug of...

Page 6: ...led VRLA valve regulated lead acid batteries Popular uses include high performance engine starting power sports deep cycle solar and storage batteries 11 OPERATING INSTRUCTIONS WARNING A spark near th...

Page 7: ...he charger will go into abort mode The display will show bAd bAt F02 COMPLETION OF CHARGE Charge completion is indicated by the green CHARGED MAINTAINING LED When pulsing the charger has switched to t...

Page 8: ...fore attempting to crank the engine again 6 After the engine starts unplug the AC power cord before disconnecting the battery clamps from the vehicle 7 Clean and store the charger in a dry location NO...

Page 9: ...OTING AND ERROR CODES Error Codes CODE DESCRIPTION REASON SOLUTION bAd bAT F01 The battery voltage is still under 10V for a 12V battery or 5V for a 6V battery after 2 hours of charging The battery cou...

Page 10: ...d Wait and try again On a severely discharged battery use the 30A Boost rate for 10 to 15 minutes to help assist in cranking I cannot select a 6V or 12V setting The charger is equipped with Auto Volta...

Page 11: ...der for repair or replacement to occur Manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher Electric Corporation and approved f...

Page 12: ...cargador del tomacorriente antes de intentar llevar a cabo cualquier actividad de mantenimiento o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO DE GASES EX...

Page 13: ...el cido de la bater a alcance el nivel especificado por el fabricante de la bater a No provoque derrames En lo que concierne a bater as que no cuentan con tapas extra bles para pilas tales como bater...

Page 14: ...del bloque motor 6 7 Al desconectar el cargador apague todos los interruptores en su caso desconecte el cable de C A retire el gancho del chasis del veh culo y luego retire el gancho del terminal pert...

Page 15: ...ndo el cargador no se encuentre cargandola Cuando se programe en el modo de carga la car tula cambiar autom ticamente a On encendido para mostrar que la carga ha comenzado y despu s mostrar el porcent...

Page 16: ...auto rectificador La corriente no llegar a las pinzas de la bater a hasta que la bater a est apropiadamente conectada Significado las pinzas no har n corto si se juntan una con otra excepto en el mod...

Page 17: ...trar bAd bAt F02 FINALIZACI N DE LA CARGA La finalizaci n de la carga se indica con el LED CARGADO MANTENIMIENTO verde Al pulsar el cargador ha pasado de modo de funci n a mantenimiento MODO DE MANTEN...

Page 18: ...tir que el cargador y la bater a se enfr en La pantalla digital indica el tiempo restante de enfriamiento en segundos La cuenta regresiva comienza en 180 y llega hasta 0 Despu s de 3 minutos la pantal...

Page 19: ...ida que el sistema de carga sea supervisado por un t cnico calificado 12 MANTENIMIENTO Y CUIDADO Con cuidados m nimos puede mantener el cargador de bater as funcionando correctamente durante a os Limp...

Page 20: ...ter a no est n conectadas en forma correcta Significado las pinzas no har n corto si se juntan una con otra No hay problema es una condici n normal El cargador no se enciende incluso al estar bien con...

Page 21: ...bAt F05 La falta de progreso se detecta despu s de 12 horas en el modo de mantenimiento La bater a no mantiene la carga Puede ser causada por una bater a descargada o la bater a podr a ser malo La ba...

Page 22: ...a trav s de un vendedor minorista no autorizado El fabricante pudiera anular esta Garant a Limitada si la etiqueta warranty void if removed es removida del producto El Fabricante no realiza ninguna ot...

Page 23: ...e Purchased____________________ Date of Purchase__________ Store Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For...

Reviews: