background image

• 9 •

START/STOP BUTTON

Use this button to start or stop the charging process, after the battery is properly connected and battery 

voltage and type have been selected. If the battery voltage is greater than 0.2 V, the display will briefly show 

“ON” when the START/STOP button is pressed. After charging has started, pressing the START/STOP 

button will cause the display to briefly show “OFF”. If the battery voltage is 0.2 V or less and the START/

STOP button is pressed, the display will show “OFF”. This indicates that charging has not started, due to 

low battery voltage. 
CHARGING LED INDICATORS
Charging (yellow/orange) lit – 
The charger is charging the battery.
Charged/Maintaining (green) lit – The battery is fully charged and the charger is in maintain mode. 
Reversed Clamps (red) flashing – The connections are reversed.
NOTE: See Operating Instructions for a complete description of the charger modes.

11.  OPERATING INSTRUCTIONS

OVERVIEW

Connect AC power and set the front panel ON/OFF switch to the ON position. Then select an unused 

charging outlet from the eight available. Connect the battery, following the precautions listed under 

sections 6 and 7. Select the appropriate Battery Voltage and Battery Type and press START. If the 

battery voltage is greater than 0.2 V, charging will begin. 

If charging begins, the Battery Voltage, Type and Display settings are saved. Then, whenever the unit has 

been off and AC power is reapplied for 10 minutes and no buttons are pressed, charging of the battery will 

resume with the saved settings from the last charging cycle. 
DISPLAY

Following power-up, the display turns off after one minute or one minute from the last key press or connection 

to a battery. With the display off, any button press (other than a display button press) will turn the display on 

for one minute or one minute from any subsequent key press or clamp connection. Also, with the display off, 

connecting the station cable clamps to a battery will show the battery voltage and keep the display on for one 

minute or one minute from any subsequent key press. However, with the display off, if the display button turns 

the display on, the display will remain on until power-down.  If the display button turns the display off (see 

Display Mode Button, in Section 10), then the above scenario, with the display off, once again applies.
CHARGING 

When charging begins, the yellow/orange Charging LED will be lit.
COMPLETION OF CHARGING

Charge completion is indicated by the green Charged/Maintaining LED. When lit, the charger has 

stopped charging and has switched to Maintain Mode of operation.
ABORTED CHARGE

If charging cannot be completed normally, charging will abort. When charging is aborted, the charger’s output 

is shut off.The display will show “BAD BAT” and an error code. See section 15, Troubleshooting and Error 

Codes. To reset after an aborted charge, press the START/STOP button to turn the charger off.
RECOVERY MODE (Non-lithium ion batteries only) 

If a battery is left discharged for an extended period of time, it could become sulfated and not accept a 

normal charge. The charger will detect this and automatically enter Recovery mode. When this mode is 

activated, the display will read “BAD BATT REC”. The display will revert to normal operation when normal 

charging begins after the battery is recovered. Recovery Mode could take up to 10 hours. If it fails, charging 

will abort and the display will read “BAD BAT F02”. For more information, see section 15, Troubleshooting 

and Error Codes.
MAINTAIN MODE

When the green Charged/Maintaining LED is lit, the charger has started Maintain Mode. This mode of 

operation is known as Float Mode Monitoring. In this mode, the charger keeps the battery fully charged 

by delivering a small current, when necessary. The voltage is maintained at a level determined by the 

battery type selected. 

Summary of Contents for DSR127

Page 1: ...el cargador de bater a de manera segura y confiable Por favor lea y siga las siguientes instrucciones y precauciones GARDER LE MANUEL D INSTRUCTION ET LISEZ LE AVANT CHAQUE UTILISATION Ce manuel expl...

Page 2: ...NSTALLED IN VEHICLE 6 FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE 7 GROUNDING AND AC POWER CORD CONNECTIONS 7 ASSEMBLY INSTRUCTIONS 7 CONTROL PANEL 7 OPERATING INSTRUCTIONS 9 USING THE VOLTMETE...

Page 3: ...GA ESTOS PASOS CUANDO LA BATER A SE ENCUENTRE FUERA DEL VEH CULO 17 CONEXIONES A TIERRA Y ENERG A DE CA 18 INSTRUCCIONES DE MONTAJE 18 PANEL DE CONTROL 18 INSTRUCCIONES DE OPERACI N 20 C MO UTILIZAR E...

Page 4: ...V HCULE 28 TAPES SUIVRE QUAND LA BATTERIE EST INSTALL E HORS DU V HICULE 28 MISE LA TERRE ET CORDON D NERGIE CA 28 DIRECTIVES D ASSEMBLAGE 29 PANNEAU DE CONTR LE 29 CONSIGNES D UTILISATION 31 UTILISE...

Page 5: ...tructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary markings on these products and on engine 1 12 This ch...

Page 6: ...ger when reading electrolyte specific gravity or filling battery 4 4 Do not operate charger in a closed in area or restrict ventilation in any way 4 5 Do not set a battery on top of charger 5 DC CONNE...

Page 7: ...alter the AC cord or plug provided if it does not fit the outlet have a proper grounded outlet installed by a qualified electrician An improper connection can result in a risk of an electric shock or...

Page 8: ...hat greater long term energy delivery than regular batteries Deep cycle batteries have thicker plates and can survive a number of discharge cycles AGM The Absorbed Glass Mat construction allows the el...

Page 9: ...ute from any subsequent key press or clamp connection Also with the display off connecting the station cable clamps to a battery will show the battery voltage and keep the display on for one minute or...

Page 10: ...ger does not have a built in load tester As such a recently charged battery could have a temporarily high voltage due to what is known as surface charge The voltage of such a battery will eventually d...

Page 11: ...de can be used to estimate the relative charge time The lower the shown the longer the charge time for a given battery The battery shown in charger mode is an indication of the relative progress of th...

Page 12: ...d or replaced F 10 The voltage on the Lithium Ion LiFePO4 battery exceeds the safe limit The charger automatically shuts off if it senses that the Lithium Ion LiFePO4 battery voltage exceeds the safe...

Page 13: ...ser to forward the unit along with proof of purchase and mailing charges prepaid to the Manufacturer or its authorized representatives in order for repair or replacement to occur Manufacturer does not...

Page 14: ...eipt because it will be required for any warranty claims This warranty is not transferable Send warranty card only DO NOT SEND UNIT TO THIS ADDRESS FOR REPAIR Mail this card to Schumacher Electric Cor...

Page 15: ...lar el cargador en forma incorrecta puede provocar riesgo de incendio o descarga el ctrica 1 10 Para reducir el riesgo de descarga el ctrica desenchufe el cargador del tomacorriente antes de intentar...

Page 16: ...en 12 V el nico nivel permitido Para ver configuraciones de tipo y voltaje de bater a consulte la Secci n 10 2 9 NUNCA cargue una bater a congelada 3 PREPARACI N PARA LA CARGA 3 1 Si resulta necesari...

Page 17: ...descarga a tierra por borne positivo conecte el gancho NEGATIVO NEGRO del cargador de bater a al borne NEGATIVO NEG N sin descarga a tierra de la bater a Conecte el gancho POSITIVO ROJO al chasis del...

Page 18: ...tal a uno de los siguientes de bater a La pantalla digital muestra un c lculo del porcentaje de carga de la bater a conectada a las pinzas de la bater a del cargador Amperaje La pantalla digital muest...

Page 19: ...que t cnicamente la bater a AGM a n se considera de pila hidroel ctrica El electrolito en un gel cell tiene aditivo de s lice que lo hace endurecer Los voltajes de recarga en este tipo de c lula son m...

Page 20: ...RRUMPIDA Si la carga no puede completarse en forma normal sta se interrumpir Cuando se interrumpe la carga la salida del cargador se apaga La pantalla se monstar BAD BAT y una codigo de error Consulte...

Page 21: ...ra probar el estado de carga de la bater a 1 Conecte las horquillas del cargador de bater as a la bater a Aseg rese de tomar todas las precauciones enumeradas en las secciones 6 y 7 2 Conecte el cable...

Page 22: ...14 MANTENIMIENTO Y CUIDADO Con cuidados m nimos puede mantener el cargador de bater as funcionando correctamente durante a os Limpie las pinzas cada vez que termine de usar el cargador Limpie el flui...

Page 23: ...t en modo cargador Presione el bot n START STOP para la bater a que est conectada al cargador Las luces del indicador se enci enden en forma err tica no se explica en la secci n Instruccio nes de Oper...

Page 24: ...o que no sean los fabricados por Schumacher Electric Corporation y que no est n aprobados para su uso con este producto La presente Garant a Limitada ser nula si el producto se utiliza en forma err ne...

Page 25: ...L como comprobante el cual le otorga todo derecho a cualquier reclamo de garant a Esta garant a no es transferible Envie tarjeta de garant a solamente NO ENV E LA UNIDAD A ESTA DIRECCI N PARA SU REPAR...

Page 26: ...ge Le fait de simplement teindre l appareil ne r duira pas les risques 1 11 AVERTISSEMENT RISQUE DE GAZ EXPLOSIFS a IL EST DANGEREUX DE TRAVAILLER A PROXIMIT D UNE BATTERIE AU PLOMB LES BATTERIES PROD...

Page 27: ...toujours d brancher la borne de mise la masse en premier S assurer que le courant aux accessoires du v hicule est coup afin d viter la formation d un arc 3 2 Assurez vous que la zone autour de la bat...

Page 28: ...a batterie 6 8 Consultez les Pourcentage de la Batterie et Dur e de Charge pour les renseignements sur la dur e du chargement 7 TAPES SUIVRE QUAND LA BATTERIE EST INSTALL E HORS DU V HICULE AVERTISSEM...

Page 29: ...dommages la propri t 6V La batterie est de type 6V et se charge au d bit correspondant Le r glage 6V n est pas disponible pour les batteries lithium ion Si une batterie de 12 V est d tect tension au d...

Page 30: ...ont un meilleur usage en d charge TR S POUSS E et peuvent durer plus longtemps dans un environnement chaud Si on utilise un mauvais chargeur de batterie pour une batterie l ments g lifi s un mauvais...

Page 31: ...ode de Conservation CHARGE AVORTE Si la charge ne peut tre achev normalement la charge avort Lorsque la charge est abandonn e la sortie du chargeur est coup e L cran affiche BAD BAT et un code d erreu...

Page 32: ...es au test de l tat de charge de la batterie 1 Raccorder les clips du chargeur de batterie la batterie S assurer de suivre toutes les pr cautions list es aux sections 6 et 7 2 Brancher le cordon d ali...

Page 33: ...en contact avec des pinces pour viter la corrosion De temps en temps nettoyer le bo tier du chargeur avec un chiffon pour garder la finition brillante et aider pr venir la corrosion Mettez les cordon...

Page 34: ...ord e au chargeur Les voyants indicateurs s allument de fa on instable non expliqu e la section Consignes d Utilisation Quelqu un a d appuyer sur un bouton lorsque le chargeur a t branch S assurer que...

Page 35: ...s accessoires utilis s avec ce produit qui ne sont pas fabriqu s par Schumacher Electric Corporation et approuv s pour une utilisation avec ce produit Cette garantie limit e est annul si le produit es...

Page 36: ...ORIGINAL puisqu il sera requis pour une ventuelle r clamation au titre de la garantie Cette garantie n est pas transf rable Envoyer la carte de garantie seulement NE PAS ENVOYER L UNIT CETTE ADRESSE P...

Reviews: