Schumacher Electric 00-99-000985 User Manual Download Page 5

 2 

Do not touch welder, attempt to turn welder on or off if any part of the 

• 

body or clothing is moist or if you are in physical contact with water or 

moisture. 
Do not attempt to plug the welder into the power source if any part of 

• 

body or clothing is moist, or if you are in physical contact with water or 

moisture. 
Do not connect welder ground clamp to or weld on electrical conduit. 

• 

Do not alter power cord or power cord plug in any way. 

• 

Do not attempt to plug the welder into the power source if the ground 

• 

prong on power cord plug is bent over, broken off, or missing. 
Do not allow the welder to be connected to the power source or attempt 

• 

to weld if the welder, welding cables, welding site, or welder power cord 

are exposed to any form of atmospheric precipitation, or salt water spray. 
Do not carry coiled welding cables around shoulders, or any other part of 

• 

the body, when they are plugged into the welder. 
Do not modify any wiring, ground connections, switches, or fuses in this 

• 

welding equipment. 
Wear welding gloves to help insulate hands from welding circuit. 

• 

Keep all liquid containers far enough away from the welder and work area 

• 

so that if spilled, the liquid can not possibly come in contact with any part 

of the welder or electrical welding circuit. 
replace any cracked or damaged parts that are insulated or act as 

• 

insulators such as welding cables, power cord, or electrode holder  

IMMeDIaTelY. 

EMF INFORMATION 

1.2 

WARNING: 

Welding current will cause electromagnetic fields as it flows 

through welding cables and internal wiring. There has been and continues 

to be some concern and research about such fields. Until the final 

conclusions of the research are reached, you may wish to minimize your 

exposure to electromagnetic fields when welding or cutting. 
To reduce magnetic fields in the workplace: 

Keep cables close together by twisting or taping them. 

• 

arrange cables to one side and away from you. 

• 

Do not coil or drape cables around your body. 

• 

Keep welding power source and cables as far away from you as practical. 

• 

connect work clamp to work piece as close to the weld as possible. 

• 

About Pacemakers

: Pacemaker wearers consult your doctor prior to 

using any welding equipment. If cleared by your doctor, then following the 

above procedures is recommended. 

Summary of Contents for 00-99-000985

Page 1: ...00 99 000985 1009 READ ENTIRE MANUAL BEFORE USING THIS PRODUCT USER S GUIDE GUIDE DE L UTILISATEUR ARC WELDER SOUDEUR D ARC LIRE ENTI REMENT LE GUIDE AVANT D UTILISER CE PRODUIT...

Page 2: ......

Page 3: ...FORMATION G N RALE DE SOUDURE 28 ENTRETIEN DU POSTE SOUDER 31 LISTE DE PI CES D TACH ES 32 GARANTIE LIMIT E 32 Pursuant to California Proposition 65 this product contains chemicals known to the State...

Page 4: ...ETY SUMMARY The National Electrical Code Occupational Safety and Health Act regulations local industrial codes and local inspection requirements also provide a basis for equipment installation use and...

Page 5: ...late hands from welding circuit Keep all liquid containers far enough away from the welder and work area so that if spilled the liquid can not possibly come in contact with any part of the welder or e...

Page 6: ...n much the same way as the sun even through lightweight clothing Wear dark clothing of heavy material The shirt worn should be long sleeved and the collar kept buttoned to protect chest and neck Prote...

Page 7: ...an result in a violent rupture immediately or at a later time as a result of rough handling Do not weld or cut in an area where the air may contain flammable dust such as grain dust gas or liquid vapo...

Page 8: ...TOXIC fumes that can cause discomfort illness and death Do not weld or cut in areas that are near chlorinated solvents Vapors from chlorinated hydrocarbons such as trichloroethylene and perchloroethyl...

Page 9: ...ciation 178 Rexdale Blvd Etobicoke Ontario M9W 1R3 www csa ca American Welding Society Standard A6 0 WELDING AND CUTTING CONTAINERS WHICH HAVE HELD COMBUSTIBLES obtainable from the American Welding So...

Page 10: ...e proper input plug you will void the manufacturer s warranty It is recommended that a qualified electrician verify the actual voltage at the receptacle into which the welder will be plugged and confi...

Page 11: ...n the welder Extension cord lengths longer than 25 feet will require heavier wire gauges to compensate for voltage losses INSTALLING THE ELECTRODE HOLDER 2 6 Attach the electrode holder to the electro...

Page 12: ...sing By doing this you will gain a feel for how changes in these welding variables affect the weld If you have not welded before you will need to develop welding skills and techniques as well The self...

Page 13: ...welder will function again However you should wait at least 10 minutes after the thermal protector opens before resuming welding even if the protector resets itself sooner or you may experience less...

Page 14: ...be performed in any of the four basic positions Flat Horizontal Vertical and Overhead Flat welding is generally easier faster and allows for better penetration Overhead welding is the most difficult...

Page 15: ...between the rod and the grounded metal melts the wire and the flux The rod wire joins with the base metal in the work piece to form the weld bead The burning flux forms a gas shield around the arc an...

Page 16: ...nsile strength of the deposited metal in thousands of pounds per square inch In this instance 60 indicates the melting rod will have a minimum tensile strength of 60 000 p s i The third number indicat...

Page 17: ...T 6 Part Number Description 3599000200 HANDLE 0699000218 ELECTRODE HOLDER 2299000549 GROUND CLAMP 4999000103 WELDING HELMET 4999000104 WELDING GLOVES 4999000105 WELDING BRUSH Optional on some models L...

Page 18: ...equential damage claims incurred by purchasers users or others associated with this product including but not limited to lost profits revenues anticipated sales business opportunities goodwill busines...

Page 19: ...glements locaux ainsi que les inspections locales constituent galement des bases de r f rence l installation l utilisation et l entretient de ces quipements RISQUES DE CHOCS LECTRIQUES 1 1 AVERTISSEM...

Page 20: ...prise d alimentation si la broche demise la terre de fiche du c ble d alimentation est tordue cass e ou manquante Ne laissez pas le poste souder branch sur une source d alimentation ou n essayez pas n...

Page 21: ...able Si vous tes d clar apte par votre docteur il est alors recommand de respecter les consignes ci dessus RISQUES D TINCELLES 1 3 AVERTISSEMENT LES RAYONS LUMINEUX DE L ARC LECTRIQUE PEUVENT ENDOMMAG...

Page 22: ...fl chis sur la surface r fl chissante puis sur la surface r fl chissante int rieure du verre filtrant de votre casque ou de votre cran puis dans vos yeux Si une telle surface r fl chissante existe der...

Page 23: ...prenant des gaz comprim s sur des bouteilles d air ou sur toute autre recipient contenant des gaz sous pression Tout manquement cette consigne peut produire une zone cassante susceptible de provoquer...

Page 24: ...age ne soudez pas tant que vous et aux gens de votre entourage ne portez pas d quipement respiratoire masque de soudeur bouteille Ne chauffez pas de m taux rev tus ou susceptibles de contenir des comp...

Page 25: ...pour la protection des yeux et du visage peut tre obtenue aupr s de American National Standard Institute 11 West 42nd St New York NY 10036 Telephone 212 642 4900 Fax 212 398 0023 www ansi org Norme N...

Page 26: ...Hz Single Phase Amp rage Conformit 70 AAC Amp rage Max 80 AAC Tension secondaire sortie 27 VAC Facteur de marche 10 Tension max en circuit ouvert 40 VAC Liste D Agence cULus Nombre d arrangements de...

Page 27: ...ou les fiches d une rallonge UTILISATION D UNE RALLONGE LECTRIQUE 2 5 Pour garantir le fonctionnement optimal de votre poste de soudure n utilisez aucune rallonge lectrique moins que cela ne soit abs...

Page 28: ...5 et vissez la dans l crou rectangulaire 2 Enfilez nouveau la poign e dans la pince electrode bien align e 5 elle s enfile facilement Appuyez bien sur les deux parties pour que la poign e s enclenche...

Page 29: ...tentez pas de r aliser des soudures sur des pi ces ou du mat riel de valeur avant de vous tre entra n sur des chutes de m tal Les chutes de m tal sur lesquelles vous vous entra nez doivent tre du m me...

Page 30: ...es performances de l appareil et de son facteur de marche Si vous d couvrez que votre poste de soudure refuse de souder pendant plus de 1 minutes sans s arr ter r duisez l g rement la vitesse d alimen...

Page 31: ...ion d une aire de travail bien clair e 1 Le port de lunettes de protection et de v tements protecteurs par 2 l op rateur et les personnes aux alentours La disposition correcte des pi ces souder et le...

Page 32: ...oint souder Pendant le soudage les pi ces s chauffent et ont tendance se dilater Cette dilatation risque de faire bouger les pi ces C est pourquoi il est conseill d assurer les pi ces dans la position...

Page 33: ...e plus pais la baguette plus d exp rience vous avez besoin Les lectrodes pour tensions lev es en circuit ouvert telles les lectrodes 6011 7018 etc ne donneront pas de bons r sultats avec la plupart de...

Page 34: ...distance la surface de la pi ce souder avec la pointe de l lectrode comme pour allumer une allumette puis d carter rapidement l lectrode la distance requise de 3 2 mm Cette distance doit tre maintenu...

Page 35: ...e est de r parer ou de remplacer votre produit avec un nouvel appareil ou un remis neuf selon le choix du fabricant Il est de l obligation de l acheteur d exp dier l appareil accompagn des frais d exp...

Page 36: ...limites ou exclusions ci dessus peuvent donc ne pas s appliquer votre cas Cette garantie vous donne des droits l gaux sp cifiques et il se peut que vous ayez d autres droits qui varient de cette gara...

Reviews: