14
•
Find your battery’s rating on the chart below and note the charge time
given for each charger setting. The times given are for batteries with a 50
percent charge prior to recharging. Add more time for severely discharged
batteries.
BATTERy SIZE/RATING
CHARGE RATE/CHARGING TIME
4 AMP
20 AMP
70 AMP
SMALL
BATTERIES
Motorcycle,
graden,
tractor, etc.
6 - 12 AH
1 - 2 hrs
NR
NR
12 - 32 AH
2 - 5 hrs
NR
NR
CARS/TRUCKS
200 - 315 CCA
40 - 60 RC
5 ¾ - 7 ¼ hrs
1 ¼ - 1 ½ hrs
20 - 25 min
315 - 550 CCA
60 - 85 RC
7 ¼ - 9¼ hrs
1 ½ - 2 hrs
25 - 30 min
550 - 1000 CCA
80 - 190 RC 9 ¼ - 17 ½ hrs
2 - 3 ½ hrs
30 min - 1 hr
MARINE/DEEP CYCLE
80 RC
8 ¾ hrs
1 ¾ hrs
30 min
140 RC
13 ½ hrs
2 ¾ hrs
45 min
160 RC
15 hrs
3 hrs
1 hr
180 RC
16 ½ hrs
3 ½ hrs
1 ¼ hrs
MAINTENANCE INSTRUCTIONS
12.
Before performing maintenance, unplug and disconnect battery charger
12.1
(see sections 6.7 and 7.6).
After use, unplug charger and use a dry cloth to wipe all battery corrosion
12.2
and other dirt or oil from terminals, cords, and the charger case.
After every 100 hours or
12.3
whenever you see dust
accumulating on the fan
blades you should clean
both fans using com-
pressed air (as shown).
NOTE: Use the com-
pressed air on the fan
blades only. Do not blow
dirt into the fan shaft or
bearing.
These fans push a lot of air
and are precision balanced.
Excessive dirt and grime
buildup will cause the fan
to be unbalanced and wear out quickly. If the fans fail, the charger may
overheat and the thermal protection of the charger will shut it down.
Servicing does not require opening unit, as there are no user-serviceable
12.4