10.

The electronic valve does 
not spray any more. No 
liquid passes through. See 
Figure in Manual Chapter 
4.8. Product number 
803422.

1. Electronic valve is clogged.

Replace the electronic valve. Request instructions from 
service/support.

2. Electronic valve is not triggered.

1. Check on the electronic board if the LEDs (Pos. 
22/23/24/25) are working. Yes = continue with 2. No = 
Replace the electronic board.
2. Test the functions by switching the output signals on the 
electronic board. Board output 22/23/24/25. See Manual 
Chapter 4.7.
3. If all outputs are working you must replace the electronic
valve. See Manual Chapter 4.8. Product number 803422.
4. If all electronic valves are working but an electronic 
output signal is not working you must replace the 
electronic board. 