10.
The electronic valve does
not spray any more. No
liquid passes through. See
Figure in Manual Chapter
4.8. Product number
803422.
1. Electronic valve is clogged.
Replace the electronic valve. Request instructions from
service/support.
2. Electronic valve is not triggered.
1. Check on the electronic board if the LEDs (Pos.
22/23/24/25) are working. Yes = continue with 2. No =
Replace the electronic board.
2. Test the functions by switching the output signals on the
electronic board. Board output 22/23/24/25. See Manual
Chapter 4.7.
3. If all outputs are working you must replace the electronic
valve. See Manual Chapter 4.8. Product number 803422.
4. If all electronic valves are working but an electronic
output signal is not working you must replace the
electronic board.