background image

6

Water connection

Connection of the appliance to the water supply must 

be carried out by an expert. A normal water supply 
 pressure of at least 0,1 MPa (1 bar) is required for the 
water connection (with the water tap open, at least 8 

litres of water must flow in one minute). If the water 

pressure is more than 1 MPa (10 bar), a pressure reduc-

tion valve must be fitted in  series.

 

Connect the water feeds as per the installation plan 

(view further behind).

 

An IRN R160-compliant double check valve must be 

 installed at the connection point between the water 

 supply and the machine.

 

The supplied feet hoses must be used for the water 

 connection.

 

Do not connect the appliance to the mixer tap of an 

 un pressurised water heater.

 

Important, the connection points are under full water 

 pressure; check for water tightness with the tap turned 
on fully.     

 

The dirt screens at the loose end of the feed hose and in 

the solenoid valve in the appliance should only be 
 removed for cleaning purposes.

 

To prevent water damage, the stop-cock or intermediate 

valve must be closed on completion of washing. 

Soft water connection

In the case of appliances with a soft water connection, 

fit the water connection hoses to the soft and hard water

 

taps as per the installation plan (view further behind).

 

X

Open the tap and check that no water flows.

 

X

Than close the tap.

 

Note that with a soft water connection, the appliance 

parameterisation must be changed (see service instruc-
tions).

Hot water connection

In the case of appliances with a hot water connection, 

fit the water connection hoses to the hot and cold water 

taps as per the installation plan (view further behind).

 

X

Open the tap and check that no water flows.

 

X

Then close the tap.

 

The temperature of the hot water supply must not exceed 

60 °C. Otherwise, the temperature of the 

hot water 

must be reduced to the maximum temperature 

of 60 °C 

by means of a mixer connected in series.

 

Note that with a

 hot water connection, the appliance 

 parameterisation must be changed (see service instruc-
tions). 

Water outlet

Drain pump

 

During installation, do not bend the outlet hose or pull 

on the hose!

 

When leading the outlet hose into a siphon (built-in or 

below the wash basin), the connecting points must be 

secured with hose clips. Otherwise there is a risk of 

flooding! You can obtain the necessary hose clamps 

through the specialist trade.

Internal diameter

21mm

 

The water produced during washing contains detergent 
and is not drinkable. This detergent solution should be 

fed into a wastewater system designed for this purpose. 

Drain valve

Direct connection to the waste pipe, on the back.

Summary of Contents for proLine

Page 1: ...Installation instruction for professional washing machines Instruction No 760 672 AA proLine WE10...

Page 2: ...2...

Page 3: ...s visible damage X After correct installation of the washing machine do not fail to fit all the dismantled external panelling parts again X Lay hoses and cables in such a way that they do not represen...

Page 4: ...a risk of injury Front X Unfasten and remove the four hex screws to the left and to the right of the loading door with a 13mm ring spanner X Remove the red transport safety devices on both sides of th...

Page 5: ...n the corner of the room If it is attached to a stand the base of the device must be fixed securely to it with a fixing set in order to prevent it from sliding off during its spin cycle You can purcha...

Page 6: ...ft and hard water taps as per the installation plan view further behind X Open the tap and check that no water flows XThan close the tap Note that with a soft water connection the appliance parameteri...

Page 7: ...ecommended in order to increase safety the release current must be 30mA Use a fault current protective switch with the symbol The motor is provided with overload protection The main switch can be lock...

Page 8: ...T Reduced electric heat output 400V 3N Reduced mains power ON Heating 7 2 kW Motor 1 1 kW Fuse 16 AT 16kg washing machine 400V 3N 400V 2N Reduced mains power Reduced mains power OFF ON Heating 17 6 kW...

Page 9: ...10 Einbring ffnung min Ouverture min Apertura min Min opening 800 x 1500 8kg 10kg 12Kg 8kg 10kg 12Kg 777 Sachnummer Index Gez Frg Ge Format Aenderungsindex ZZ AA 14 12 2018 meg 8kg 12kg 750856 AA A4...

Page 10: ...6 1 2 3 9 20 900 x 1600 Einbring ffnung min Ouverture min Apertura min Min opening Copyright by Schulthess Maschinen AG Sachnummer Index Gez Frg Ge Format Aenderungsindex ZZ AA 09 12 2013 FAD 10 03 2...

Page 11: ...ection for liquid detergent pumps 4b is not used max flow rate for 1 connection 15l min for 2 connections 8 5l min max 5bar per connection 4b Direct connection for liquid detergent pumps 8 direct conn...

Page 12: ...12 18 d f i e Printed in Switzerland Subject to change without notice...

Reviews: