background image

05

2. Product description.

2.1 Material information

The sub-frame is made of steel which is non-corroding and powder-coated. 

2.2 Handling / transport

The sub-frame is not designed to be carried, as it is fitted with castors. 

Should you have to carry the equipment due to obstacles, ensure that all 

moving parts are tightened. Then position yourself next to the sub-frame, 

grip it on both sides under the support head and carry it to the required 

location. To transport the sub-frame, reduce all adjustments to their most 

compact size (fold up foot support, set lowest seat height etc.).

Tighten all moving parts prior to carrying!

2.3 Application areas, use according to the intended purpose

The 

fridolin maxi.

 indoor sub-frame is a medical product of risk class 1 and 

is suited exclusively for indoor use. The sub-frame is designed as substruc-

ture to accommodate seating systems or seat pans. Any other use or use 

over and above this purpose shall be considered not in accordance with 

the intended purpose.

2.3.1 Indication

The indication for the 

fridolin maxi.

 sub-frame is derived from those of the 

seating systems and seat pans.

2.3.2 Contraindications

In general, the indication for a seat pan sub-frame in combination 

with a seating system or a seating pan should be accompanied by a  

medical-orthopaedic specialist. It should therefore be clarified prior to 

procurement whether contraindications exist for the patient. In general, 

any type of pain represents a contraindication.

Summary of Contents for FRIDOLIN Maxi

Page 1: ...Instructions for use fridolin maxi The functional sub frame for indoor use fridolin maxi...

Page 2: ...for use carefully prior to initial commissioning of the product and to observe them Please note that guidelines and representations in these Instructions for use may deviate from your product due to...

Page 3: ...overview 07 3 Settings 08 3 1 Seat height 08 3 2 Seat angle 08 3 3 Dual castors 08 4 Accessories 09 4 1 Maxi push handle 09 4 2 foot support 09 4 3 Plug in footrest 09 4 4 Wheel base extension 10 5 C...

Page 4: ...tect the environment to prevent environmental pollution and to improve the recycling of raw materials please note the disposal instructions in points 1 3 1 and 1 3 2 1 3 1 Packaging The packaging of t...

Page 5: ...areas use according to the intended purpose The fridolin maxi indoor sub frame is a medical product of risk class 1 and is suited exclusively for indoor use The sub frame is designed as substruc ture...

Page 6: ...y mounted and adjusted Please ensure that none of the user s extremities are in the respective area when making adjustments of any kind to minimise the risk of injury Users with visual reading or ment...

Page 7: ...tant components as well as the terms which you will find in these Instructions for use Push handle Gas pressure springs for angle adjustment of the seating unit Foot pedal for angle adjustment of the...

Page 8: ...s on the seat angle adjustment must be readjusted in height This is done after dismantling the screw connections at the lower end of the two gas pressure springs and moving the lugs B in the hole patt...

Page 9: ...the support head After the respective foot support has be inser ted in the support head C and the depth has been set the knee angle can be fixed using the two clamping levers D The lower leg length ca...

Page 10: ...ntion to the sewn in care labels such as A B on the respective element Please also pay attention to our general clea ning and hygiene advice This can be found at www schuchmann de mediathek 5 1 2 Disi...

Page 11: ...urer s specifications Disinfect according to the manufacturer s specifications as required Damages to the frame mounting parts and accessories cracks breaks corrosion bent or missing parts Strength of...

Page 12: ...f use and re use The expected duration of use of our product dependent on the usage in tensity and amount of re use totals up to 8 years if the usage takes place in accordance with the information in...

Page 13: ...acturing fault occur within this time period we shall after carriage paid return to us view the indicated damage and if applicable either repair or deliver a new product at our discretion A Height of...

Page 14: ...aufgef hrten Richtlinien und Standards entspricht is are in conformity with the requirements of the below listed directives and standards Verordnung EU 2017 745 ber Medizinprodukte vom 05 April 2017 R...

Page 15: ...dress of the manufacturer specialist dealer supplying the product This product was manufactured by 8 Identification This product has been delivered by the following specialist dealer Schuchmann GmbH C...

Page 16: ...schuchmann de GA 22 EN_1 0...

Reviews: