background image

11850-029

II

R1.1, July 2021

Summary of Contents for nvent 11850-029

Page 1: ...1U 4 slot MTCA Shelf User s Manual Product Number 11850 029 Doc No 63972 397_R1 1 July 2021...

Page 2: ...Management System to EN ISO 9001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further developme...

Page 3: ...ane Topology 4 3 2 Backplane Features 5 3 3 Intelligent Platform Management Bus IPMB 5 3 3 1 IPMB L 5 3 4 Power Management 5 3 5 Third party clock module 6 4 Cooling 8 4 1 Air Filter 8 4 2 Air filter...

Page 4: ...11850 029 II R1 1 July 2021...

Page 5: ...3 References and Architecture Specifications PICMG MTCA 0 Specification www picmg com PICMG AMC Base Specification www picmg com Hazardous voltage This is the electrical hazard symbol It indicates th...

Page 6: ...tegration of an optional 3rd party eCLK module that routes external clock and trigger signals to the AMC slots Features Shielded steel case 2 AMC Double Mid size slots with RTM slots 2 AMC Single Mid...

Page 7: ...age 1 eMCH 7 AC input with Mains line switch and fuse 2 AMC slots 1 3 8 PSU 3 AMC slots 2 4 9 Air filter 4 ESD Wrist Strap Terminal 10 Fans rear section 5 RTM slots 11 Fans front section 6 Ground Term...

Page 8: ...HSC_1 EN_HSC_2 IR_HotSwap 1 IR_HotSwap 2 MP_2 MP MP_1 MP_3 MP_4 3 3V DC DC Converter Port 12 Port 13 Port 14 AMC2 Double Mid Size RTM Port 15 Triggers Clocks Interlocks Port 17 20 2 AMC3 Single Mid Si...

Page 9: ...AMC1 port 8 11 to AMC2 port 4 7 AMC2 port 8 11 to AMC4 port 8 11 Note As 4 PCIe MUX s are in the fat pipe extended fat pipe backplane signal lines only AMC modules that support PCIe on fat pipe exten...

Page 10: ...t eClock connected to FatPipe 17 RxFB 1 eClock AMC1_TCLKC inout AMC1 port 2 to eClock RX TCLKC to AMC1 Future use for SATA NVME drive on eClock or intelligent eClock connected to FatPipe 18 TxFB 3 eCl...

Page 11: ...er Payload Power 12V Current Capability 2 8A max derated to 1 5A 52 MLVDS 20 TX inout Bus LVDS Port 20 TX 53 MLVDS 18 TX inout Bus LVDS Port 18 TX 54 GND Ground 55 MLVDS 18 TX inout Bus LVDS Port 18 T...

Page 12: ...out after removing the top cover The filter meets the requirements of the Telcordia Technologies Generic Requirements GR 78 CORE specification 4 3 Cooling The MicroTCA Shelf is equipped with seven 12...

Page 13: ...rdous voltage Always remove mains line connector before carry out any assembly work Caution The unit is designed in accordance with protection class 1 It must therefore be operated with protec tive ea...

Page 14: ...s and verifies local sensor data of the chassis and installed FRU devices and supplies MicroTCA power and cooling concepts by accessing the chassis integrated power supply and fan coolers Remote admin...

Page 15: ...MCH front panel Note When executing the bootloader all LEDs will be put on OK FAIL 1 2 AMC 3 4 Type Function LED AMC 1 AMC 4 Blink Short Reading FRU information M1 Blink Slow Waiting for HS Handle bei...

Page 16: ...automatically by the windows update may take up to a few minutes Table 4 Basic CLI Commands Baudrate 115200 Data 8 bit Parity None Stop 1 bit Flow control None COM The devices COM address defined by...

Page 17: ...ttings list by hitting the RETURN button until you reach the topic Use alternate PCIexpress configuration Type y and hit RETURN Go to the end of the list and save the changes to flash Reboot CFG confi...

Page 18: ...ess y n RET y RMCP session activity timeout minutes 60 min RMCP session activity timeout seconds 0 sec Enter session activity timeout dec minutes RET 60 0x3c Enter session activity timeout dec seconds...

Page 19: ...configuration modes 0 no action 1 print complete configuration 2 modify MCH global configuration 3 modify ShM configuration 4 modify CM configuration 5 modify SEL configuration 6 modify DHCP configur...

Page 20: ...ve changed slightly and will prompt you to enter a password By default the password is nat To leave the bootloader without touching anything just click on Leave Bootloader By clicking on submint the u...

Page 21: ...m 19 Width w o mounting brackets 443 60 mm Depth approx 373 mm Weight Weight completely assembled approx 5 8 Kg Power Supply Input Voltage 100 VAC to 240 VAC Mains Frequency 50 Hz to 60 Hz Input Curre...

Page 22: ...11850 029 18 Technical Data R1 1 July 2021 6 1 Dimensions 43 60 mm 482 60 mm 443 50 mm 373 06 mm...

Page 23: ......

Page 24: ...Schroff GmbH Langenalber Str 96 100 75334 Straubenhardt Germany Tel 49 7082 794 0 Fax 49 7082 794 200...

Reviews: