11990-704/705/706/707 (2-Slot ATCA Shelf)
Safety
2
R1.2, March 2018
1.3 References and Architecture Specifications
• User Manual Shelf Manager ACB-V, order-no.: 63972-243
• User Manual Shelf Alarm Panel, order-no.: 63972-230
• Pigeon Point Systems IPM Sentry Shelf-External Interface Reference
(
• PICMG
®
3.0 Revision 3.0 AdvancedTCA® Base Specification
(
)
1.4 Product Definition
The Schroff 11990-704/ -705/ -706/ -707 are 3 U / 2 Slot AdvancedTCA Shelves for Enterprise
or Development applications. Different versions are available:
•
11990-704:
Base Interface in a
Hub/Hub
configuration supporting ShMC cross connects,
dedicated slots for two Schroff ACB-V Shelf Managers and one Shelf Alarm Panel (SAP),
fans controlled by the Shelf Manager or through autonomous fan controller,
DC Power
Entry Module.
•
11990-705:
Base Interface in a
Hub/Hub
configuration supporting ShMC cross connects,
dedicated slots for two Schroff ACB-V Shelf Managers and one Shelf Alarm Panel (SAP),
fans controlled by the Shelf Manager or through autonomous fan controller,
AC Power
Entry Module.
•
11990-706:
Base Interface in a
Node/Node
configuration, dedicated slots for two Schroff
ACB-V Shelf Managers and one Shelf Alarm Panel (SAP), fans controlled by the Shelf Man-
ager or through autonomous fan controller,
DC Power
Entry Module.
•
11990-707:
Base Interface in a
Node/Node
configuration, dedicated slots for two Schroff
ACB-V Shelf Managers and one Shelf Alarm Panel (SAP), fans controlled by the Shelf Man-
ager or through autonomous fan controller,
AC Power
Entry Module.