background image

1e

3/14

Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue

 de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to c

hanges without notice.

www.schreder.com

C5 - SIDE CABINET

1d

mains door
multipurpose door

beyond light door

1960mm

77.2in

C4 - 3 DOORS

00-63-030 | DOC-0016143 Rev C | 11-2019

TYPES OF POLES 

mains door

access door

- Door without 

 

cut out

- EV charger

- Intercom

- Door with 

 

cut out 

(Power Sockets)

145mm

5.7in

145mm

5.7in

145mm

5.7in

666mm

26.2in

193mm 

7.6in

706mm

27.8in

1050mm

41.3in

400mm

15.7in

446mm

17.6in

666mm

26.2in

193mm 

7.6in

145mm

5.7in

145mm

5.7in

450mm

17.7in

1250mm

49.2in

150mm

5.9in

65mm

2.6in

80mm

3.2in

Summary of Contents for SHUFFLE POLE

Page 1: ...10 2660 8 7 47 104 2470 8 1 43 95 2280 7 5 40 88 mm ft kg lb 6840 22 4 125 276 6650 21 8 121 267 00 63 030 DOC 0016143 Rev C 11 2019 1 14 Copyright Schr der S A 2018 Executive Publisher St phane Halle...

Page 2: ...pyright Schr der S A 2018 Executive Publisher St phane Halleux Schr der International Services sa B 4000 Li ge Rue de Mons 3 Belgium The information descriptions and illustrations herein are only of a...

Page 3: ...chreder com C5 SIDE CABINET 1d mains door multipurpose door beyond light door 1960mm 77 2in C4 3 DOORS 00 63 030 DOC 0016143 Rev C 11 2019 TYPES OF POLES mains door access door Door without cut out EV...

Page 4: ...iptions and illustrations herein are only of an indicative nature and subject to changes without notice www schreder com 00 63 030 DOC 0016143 Rev C 11 2019 TYPES OF DOORS MAINS DOOR CHRISTMAS DOOR MU...

Page 5: ...for exible empty pipe Fill the moulding with concrete C16 20 B20 After concrete curing remove jig 3 4 Using the supplied jig place the anchor bolts inside the concrete moulding leaving threaded extre...

Page 6: ...n guiding the electrical cables to the compartment base Fully tighten the nuts following the recommended torque values Check the correct vertical alignment of the pole Assemble the top washer and nut...

Page 7: ...osion protection system of the lighting column is not damaged c when the hole is back lled with concrete the concrete is to extend from the base of the lighting column to ground level d where paving o...

Page 8: ...rations herein are only of an indicative nature and subject to changes without notice www schreder com Perform nearby soil compaction preferably with a mechanical vibration compacter Check the correct...

Page 9: ...are only of an indicative nature and subject to changes without notice www schreder com 00 63 030 DOC 0016143 Rev C 11 2019 5 6 4 1 x SCR Tri Head DIN 22424 C 6 The lock plate has to be tightened to t...

Page 10: ...de Mons 3 Belgium The information descriptions and illustrations herein are only of an indicative nature and subject to changes without notice www schreder com 00 63 030 DOC 0016143 Rev C 11 2019 C RA...

Page 11: ...information descriptions and illustrations herein are only of an indicative nature and subject to changes without notice www schreder com 240 156 185 4 For Decorative lighting Powered by Mains Lighti...

Page 12: ...on descriptions and illustrations herein are only of an indicative nature and subject to changes without notice www schreder com Socket Cable holder Cable holder M5 T25 Door cut out with plug L M N O...

Page 13: ...s and illustrations herein are only of an indicative nature and subject to changes without notice www schreder com Depending on the version Tool is delivered with the pole 6 TYPE F Schuko Socket 16 Am...

Page 14: ...ice www schreder com Socket Connect Cables to Mains Box See DOC 0016042 Boxes and Cabling Installation Instruction Cable holder Cable holder T U V W X Open socket cover Open the maintenance ap using t...

Reviews: