SCHOTT KL 1500 H User Manual Download Page 7

KL 1500 H

 

2.  Oper

 

2.1  Light

 

 

Start by lo
Insert the l

Attention: W
fits into one

   

Safe

ATTENTIO

Light guide
down befo
replacing t

 

The light g
prevents th
opening.  T
the light gu

If the light 
It will turn b
affect the b

As long as
the LCD di

 

2.2  Powe

 

Insert the 
(optional  a
on the bac
connected 

Please ens
source onl

 

When repla
used. 

HAL / KL 1

ration

 

t guide co

oosening th

ight guide a

When inser
e of the two

ety inform

ON! 

es can beco

ore replacing

he light guid

guide socke

he operatio

This protect

uide is exch

guide is rem

back on as 

brightness l

s there is no

isplay (5) w

er connec

three pin 

accessory)  i

ck of the in

 to the main

sure that yo

y within the

acing the po

1500 H - O

onnection 

  

e locking s

as far as it w

rting light g

o guide slots

mation: 

ome hot du

g it. It is re
de. A warni

et (2) is equ
on of the lam

ts the user 

hanged by m

moved from

soon as the

evel set at t

o light guide

will show the

tion: 

power cor

into the des

nstrument.  T

ns supply (1

ou operate y

e specified v

ower cord t

Operating 

  

screw (3) o

will go and t

uides with a

s. 

ring prolong
commende

ng sign has

ipped in ad

mp unless 

from being

mistake befo

m the light g

e light guide

the light inte

e in the ligh

e  error mes

rd of type 

signated pl

The instrum

100-240 V A

your KL 150

voltage rang

he same ty

instructio

of the light g

tighten the 

a locating p

ged use. Pl

ed to turn of

s been attac

ddition with 

a recomme

g blinded du

ore the light

uide socket

e is reinsert

ensity settin

ht guide soc

ssage "No L

H05VV-F3

ug in socke

ment needs

AC, 50-60 H

00 HAL cold

ge. 

ype must be

ons

guide sock

locking scre

pin, care mu

ease make

ff the light s

ched       to 

a sensor sy

ended light 

uring opera

t source is t

t (2) during 

ted into the 

ng (4). 

cket (2) whe

Light Guide"

G0,75 

et (10) 

 to be 

Hz). 

d light 

    

et (2) by tu

ew by turnin

ust be taken

e sure that t

source for a

remind you

ystem (auto

guide is se

tion without

turned off a

operation, 
light guide 

en the light

". 

urning it an
ng it clockw

n to ensure

the light gui

about 5 min

u of this nec

omatic switc
eated in the

t light guide

at the on/off 

the lamp w

socket (2).

t source is s

 

6/15 

nti-clockwise

wise. 

e that the pi

ide is coole
nutes befor

cessity. 

ch off) whic

e designate

e, e.g. whe

switch (1).

will switch of

This will no

switched on

 

e. 

ed 

re 

ch 

ed 
en 

ff. 
ot 

n, 

 

Summary of Contents for KL 1500 H

Page 1: ...User Manual Distribution in the UK Ireland Lambda Photometrics Limited Lambda House Batford Mill Harpenden Herts AL5 5BZ United Kingdom E info lambdaphoto co uk W www lambdaphoto co uk T 44 0 1582 764...

Page 2: ...erating instructions 1 15 Operating instructions KL 1500 HAL KL 1500 H Status March 2016 different name KL1500H possible In this operating instructions for the sake of simplicity only the KL 1500 HAL...

Page 3: ...ion 6 2 1 Light guide connection 6 2 2 Power connection 6 2 3 Start up procedure 7 2 4 Light intensity setting 7 2 5 LCD display indication and settings 8 2 6 Supplementary optics 9 2 7 Filter slide 1...

Page 4: ...lectronic light intensity setting 2 4 5 LCD display 2 5 6 Pivot lever for supplementary optics 2 6 7 Filter slide 2 7 8 Carrying handle 1 9 Lamp compartment with halogen cold light reflector lamp 3 10...

Page 5: ...n g incident l ials To av following ins Operating n ger caution surface rce is intend he intensive d out High guides standard th ght source ive and full co uirements o AN CSA C2 ese instruc ve the ope...

Page 6: ...ace f before bein eveloped fo sed in explo power suppl be opened d out by th r of the syst e for damage instructio er of fire guide exit w ammable lig appropriate level in ord all light g ance at even...

Page 7: ...with a s ring prolong commende ng sign has ipped in ad mp unless from being mistake befo m the light g e light guide the light inte e in the ligh e error mes rd of type signated pl The instrum 100 24...

Page 8: ...our temperature Kelvin at the light guide exit by means of a single press on the brightness control 4 Please note that this indicator is not an exact physical quantity and therefore subject to a certa...

Page 9: ...in per cent or Kelvin see Point 2 4 You can toggle the display by briefly pressing the light intensity setting rotary dial 4 once Indicator of lamp operating time You can have the LCD display 5 indic...

Page 10: ...sity setting rotary dial 4 5 seconds to access the menu control Next select the Reset submenu Turn the light intensity setting rotary dial 4 to select Reset and confirm your selection with a brief pre...

Page 11: ...r slide 7 the filter sl the filter slid has cooled of this nece e 7 from th lint free glo e filter is the ket left to t source for a his position instructio which can lide must a de in an int d down...

Page 12: ...t 6 4 into th the screws back on and Operating nd lamp so to remin ce is switch to the devic by pressin t will go Mo off the sock r Point 6 4 de the lamp on the light guaranteed cements start by ca sc...

Page 13: ...d faults are commonly displayed on the LCD display 5 see Point 2 5 Overheating Insufficient cooling temperature monitor has triggered Open Circuit Lamp circuit interrupted lamp defective or missing No...

Page 14: ...ange of accessories is available for your KL 1500 HAL A separate brochure gives you comprehensive information turn to page 15 for the order address Only SCHOTT light guides and accessories guarantee p...

Page 15: ...t kg approx 4 2 Cooling Axial fan Ambient temperature C 5 40 Relative humidity at 31 C ambient temperature 85 31 C to 40 C ambient temperature linearly decreasing to 75 Air pressure hPa 800 1060 Trans...

Page 16: ...t and t ymbol means th posed of separa eached their en TT AG Lighting m that customers e make use of th elping preserve ore information o chott com lightin Operating dle diameter mm values lm lm lm an...

Page 17: ...ited Kingdom E info lambdaphoto co uk W www lambdaphoto co uk T 44 0 1582 764334 F 44 0 1582 712084 Distribution in the UK Ireland Lambda Photometrics Limited Lambda House Batford Mill Harpenden Herts...

Reviews: