Run Condition
1. Power: AC110V/220V
2. Underwater Lamp: AC12V
3. Water Pump: AC110V/220V
4. Heater: AC110V/220V
5. Air Pump: AC110V/220V
Operation Manual
1. ( )Power on/off key, Other function can be used only when power is on.
3
2. ( )O on/off key
3
Other key will be no action except for the power key when the O is on.
3
3
O will be stopped in 15 minutes when O is on.
3
O key will be no action when other function key is pressed.
3
O key can be action only when the power key is off and then is on .
3. ( )Heater control
The heater can be work normally only when the water pump is open.
( )Temperature can be set when the heater key is on .
Temperature can be adjusted from 10
to 50
.
Temperature display window will flash when the temperature is set.
And will display current water temperature in five seconds.
4. ( )FM Radio on/off key
( )Radio volume up and down key.
They can select mem channel when mem key is on the select station state or on the
mem store state.
( )They can turn the radio step by step when they are pressed on short time.
They can search the station when they are pressed on long time.
( )It can select mem channel when it is pressed on short time.
It can be the storing station state when, it is pressed on long time.
And it can store station when it is pressed again.
5. ( )Air pump on/off key
Air pump can be opened only when the water level is at the set position.
And will be automatically closed when the water level is low.
6. ( )Water pump on/off key
Water pump can be opened only when the water level is at the set position.
And will be automatically closed when the water level is low.
7. ( )Underwater lamp on/off key
8. Outlet valve control, it will outlet water for 3 minutes after 10 minutes.
When it detects the anhydrous state from the having water state.
Precautions
1. The installation should be carried out by a qualified technician and creepage protector
should be installed in the place easily to be controlled.
2. The electronic parts should be well grounded, otherwise, the manufacturer will not be
liable for any loss or consequences occurred.
3. The load capability of the power supply should be considered during installation, or it
affects the normal operation of the product or may lead to accident!
4. For any functions can not be activated through the ways mentioned above, please
contact a certified technicians or local dealer.
5. If you don't use the product for a long time, please disconnect the main power supply.
6. Parts containing live parts, except parts supplied with safety extra-low voltage not
exceeding 12V, must be inaccessible to a person in the bath.
7. Earthed appliances must be permanently connected to fixed wiring.
8. Parts incorporating electrical components, except remote control devices, must be
located or fixed so that they cannot fall into the bath.
9. The appliance should be supplied through a residual current device (RCD) having a
rated residual operating current not exceeding 30mA.
10. Make sure that the wire is laid correctly.
11. Make sure that the equipotential connection is done correctly.
12. The means having a contact at least 3.0mm separation in all poles that provide full
disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
13. If the supply cord is damaged,it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
Earthing Marking
Equipotential
Switch Marking
10
09
Instruction of Using Our Products
Instruction of Using Our Products