10
09
Instruction of Using Our Products
Instruction of Using Our Products
1. Power: AC110V/220V
2. Underwater Lamp: AC12V
3. Water Pump: AC110V/220V
4. Heater: AC110V/220V
5. Air Pump: AC110V/220V
1. ( )Power on/off key, Other function can be used only when power is on.
3
2. ( )O on/off key
3
Other key will be no action except for the power key when the O is on.
3
3
O will be stopped in 15 minutes when O is on.
3
O key will be no action when other function key is pressed.
3
O key can be action only when the power key is off and then is on .
3. ( )Heater control
The heater can be work normally only when the water pump is open.
( )Temperature can be set when the heater key is on .
Temperature can be adjusted from 10
to 50
.
Temperature display window will flash when the temperature is set.
And will display current water temperature in five seconds.
4. ( )FM Radio on/off key
( )Radio volume up and down key.
They can select mem channel when mem key is on the select station state or on the
mem store state.
( )They can turn the radio step by step when they are pressed on short time.
They can search the station when they are pressed on long time.
( )It can select mem channel when it is pressed on short time.
It can be the storing station state when, it is pressed on long time.
And it can store station when it is pressed again.
5. ( )Air pump on/off key
Air pump can be opened only when the water level is at the set position.
And will be automatically closed when the water level is low.
6. ( )Water pump on/off key
Water pump can be opened only when the water level is at the set position.
And will be automatically closed when the water level is low.
7. ( )Underwater lamp on/off key
8. Outlet valve control, it will outlet water for 3 minutes after 10 minutes.
When it detects the anhydrous state from the having water state.
Operation Manual
Run Condition
1. Switch on the power supply
2. Turn on the cold/hot water switch, and adjust to the suitable temperature. Use the switch
to choose the faucet or handheld shower to let water in.
3. Don't press the water pump switch unless the water level in the bathtub reach to or
higher than the jets position.
4. Use air regulator to adjust the massage power.
5. Rotate the handheld shower to adjust the massage effection.
6. Use light switch to turn on/off the underwater light.
7. Press water pump switch, turn off the pumps, and drain the water after use.
8. Turn off the power supply.
Usage
Troubleshooting
Trouble
Possible Reason
Try this to solve
Water pump
Don't work.
Power supply is not well connected,
the creepage protector disconnect .
Turn on the power supply, and connect
the creepage protector.
Clean the water pump impeller.
Water pump impeller was stuck
by sundries.
Press the water pump switch.
The water pump switch is off.
Plug the power supply in.
Power supply plug don't insert or no
enough power supply.
Repair or replace the water pump.
Water pump trouble.
Air pump don't
work.
No enough power supply.
Check the circuitry and plug the power
supply in.
Press the air pump switch.
Switch is off.
Plug the power supply in.
Power supply plug don't insert.
Massage power
can't be adjusted.
Voltage problem.
Check voltage.
Adjust switch is off or has problem.
Water Circulation is blocked.
Check, replace the switch.
Clean the water circulation.
Bathtub don't
stand horizontally.
Adjustable foot is not well-adjusted.
Adjust the Adjustable foot.
Water leakage.
Obturating ring is not good.
Replace the obturating ring.
Nut is loose.
Connect part is not well connected.
Screw down the nut.
Pay attention to the connect part
conglutination