Adapting to various types of gas 

 

Warning:

 Servicing should be carried out only by 

authorised personnel.  
 
To adapt the hob to a different type of gas other 
than the default type (indicated by the label 
placed on the upper part of the hob or on the 
packaging), the burner nozzles should be 
replaced as follows: 
 
 

1.  Remove the hob grids and slide the 

burners off their seats. 
 

2.  Unscrew the nozzles using a 7 mm 

socket spanner (fig.10), and replace 
them with nozzles for the new type of 
gas (see table 1 “Burner and nozzle 
characteristics”). 
 

3.  Reassemble the parts following the 

above procedure in the reverse order. 
 

4.  Once this procedure is finished, replace 

the old rating sticker with one indicating 
the new type of gas used. Sticker are 
available from any of our Service 
Centres. 

 

 

 

 
 

   

   

Setting the burners to minimum (only for 
natural gas) 

1.  While the hob is switched off, press the 

power button T1. Press the lock button T2 
(D1 lights up). 

2.  Press the buttons T2, T5 and T9 

simultaneously and hold them down until 
the numerical value 01 appears on the 
display 02; on the displays D3, 4, 5 and 6 
a numerical value appears which 
indicates the set minimum level. This 
level ranges from 9. (the point 
corresponds to a negative indication, i.e. -
9) to 9: there are therefore 19 minimum 
levels to choose from.  

3.  Press the + or – button corresponding to 

the burner you are adjusting; the burner 
will be activated at its maximum level to 
begin with, and will then be adjusted to 
the minimum setting value indicated at 
that moment by the display corresponding 
to that burner.  

4.  Use the + or – buttons corresponding to 

the relevant burner to increase or 
decrease the minimum level; if the 
minimum level is too low, causing the 
burner to switch off or operate at such a 
low level that the thermocouple does not 
detect the flame, the burner operates at 
its maximum level for a few seconds and 
then returns to the minimum level. 

After replacing the nozzles, change the hob 
setting using the control panel as follows: 

1.  While the hob is switched off, press the 

power button T1. 

2.  Press the lock button T2 (D1 lights up). 
3.  Press the buttons T2, T7 and T11 

simultaneously, holding them down until 
a numerical value appears on the display 
D2. At this point, with the hob set to 
natural gas at 1.0kPa, the display shows 
01;  

4.  to convert the hob to operation with 

ULPG at 2.75kPa 29, press the T4 
button once, so that the value 02 
appears on the display D2. The hob will 
allow 2 adjustments to be made: 01 and 
02, which correspond to natural gas at 
1.0kPa mbar and ULPG at 2.75kPa 
respectively. 

Summary of Contents for B 40 L EC.1 SF

Page 1: ...ion Data Plate Burner Injector Specification Description of the Appliance 9 Overall View Start up and Use 10 13 Practical advise on using the burners B 40 L EC 1 SF Precautions and Tips 14 General Saf...

Page 2: ...ouched such as through a cupboard or a pot drawer a panel should be fixed 15mm below the base of the hotplate to prevent accidental contact The base of the hotplate is very hot during operation Data L...

Page 3: ...tion the seal provided along the perimeter of the hob as illustrated in Fig 5 Brackets for fixing worktops to the cabinet have been provided and these should be fitted as shown in detail S Fig 3 2 Bui...

Page 4: ...st be fitted underneath the hob as insulation It should be fixed at least 20 mm away from the hob casing The appliance must be fitted to the kitchen cabinets using suitable fixing accessories these ar...

Page 5: ...l connection has been made and is compliant with AS NZS 3000 wiring rules Before connecting to the power supply make sure that The appliance is earthed and the plug is compliant with the law The socke...

Page 6: ...level ranges from 9 the point corresponds to a negative indication i e 9 to 9 there are therefore 19 minimum levels to choose from 3 Press the or button corresponding to the burner you are adjusting t...

Page 7: ...efore Leaving Check all connections for gas leaks with soap and water DO NOT use a naked flame for detecting leaks Ignite all burners to ensure correct operation of gas valves burners and ignition Tur...

Page 8: ...B 40 L EC 1 SF Gas Appr No GSCS20141 Natural Gas 1 0kPa ULPG 2 75kPa Injector By pass MJ h Injector By pass MJ h Rapid 1 29 3 8 0 8 Closed 8 5 Semi Rapid 1 1 3 6 0 64 Closed 5 3 Aux 0 8 4 3 2 0 5 Clos...

Page 9: ...and power Use the diameter of the cookware to choose the most appropriate burner to cook with Control Knobs for GAS BURNERS adjust the power or the size of the flame GAS BURNER ignition enables a spe...

Page 10: ...MIN POWER LEVEL WITH SUBSEQUENT POWER INCREASE UNTIL IT REACHES THE MAX LEVEL T 11 BUTTON USED TO IGNITE THE BURNER INDICATED ON THE GRAPHIC DISPLAY AT THE MAX POWER LEVEL WITH SUBSEQUENT POWER REDUC...

Page 11: ...point if you continue pressing the button it is possible to decrease the power level until it reaches level 1 or the burner is switched off level 0 SWITCHING OFF A BURNER Press the and buttons corresp...

Page 12: ...keypad is locked the display D1 is activated after a further minute a buzzer sounds again and the hob switches off once and for all with the keypad remaining locked Nevertheless in every operating st...

Page 13: ...WHILE IT IS IN OPERATION WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN CARAVANS IT SHALL NOT BE USED AS A SPACE HEATER This appliance is not intended for use by persons including children w...

Page 14: ...f the appliance Contact a Service Centre see Assistance Always make sure that pan handles are turned towards the centre of the hob in order to avoid accidental burns Do not use unstable or deformed pa...

Page 15: ...ld be washed frequently with warm water and soap and any burnt on substances removed For hobs which light automatically the terminal part of the electronic instant lighting devices should be cleaned f...

Page 16: ...pressed in long enough to activate the safety device The gas holes are not blocked in the area corresponding to the safety device The burner does not remain lit when set to minimum The gas holes are...

Reviews: