GBA Z 0675 2 E
BA
Page 16 of 29
November 9, 2020
Last revised 11-2020
Rev. 2
Scho
ll Ap
parat
eb
au
G
mb
H &
C
o
.
KG
4
O
PERATION TEST
CAUTION
The glass ceramic zone is warmed up from the heat
of the serving pan. To avoid injuries (burning) do not
touch this area.
Use exclusively the SCHOLL GN equipment for the RTCSmp Install Hold-Line heat retention unit.
• Put some water in the serving pan and place it in the center of the heating area.
• Turn the control knob to an ON-position, temperature between 50-100°C. The 7-Segment display
underneath the ceran glass shows the choosen temperature and the current temperature, the water
will be heated.
• Take the serving pan away from the heat retention area, power transmition stops.
• Place the serving pan back on the heat retention area, the heating retention process will continue.
• Turn the control knob in the OFF-position, the heat retention process will stop, if temperature is over
50°C, display shows HOT, otherwise it turns off.
The indication of the measured temperature means that energy is being transferred to the bottom of the
SCHOLL GN equipment.
If the display remains off, check the following:
• Is the induction unit connected to the mains supply?
• Is the control knob in ON positon?
• Do you use the suitable SCHOLL GN equipment?
• Is the serving pan placed in the center of the heating area?
If in spite of all positive controls and tests, the induction unit does not work, refer to the Fault Finding Sec-
tion.