Scholl 29065/H Instructions For Use Manual Download Page 5

GBA B 0500 1 E 

 

BA 

Page 5 of 27 

Mai 18, 2020 

Last revised 05-2020 

 

Rev. 1 

Scho

ll Ap

parat

eb

au

 G

mb

H & 

C

o

KG

 

 

 

C

ONVENTIONS

 

1.1  P

ICTOGRAMS 

 

G

ENERAL SAFETY NOTES

 

 

 

Be sure to observe these Instructions for Use as well as the safety notes to prevent 
injuries or damage to health or property. Do not alter or modify this appliance. 

 

Never use a defective appliance. If you suspect the unit of being faulty or discover 
an  unusual  noise  or  smell,  turn  off  the  power  switch  and  pull  the  plug  out  of  the 
socket-outlet,  or  otherwise  disconnect  the  appliance  from  the  mains  and  de-
energize it (i.e., ensure that it no longer carries any voltage). Do not use this appli-
ance when its power cord is damaged. 

Failure to observe this warning may result in a fire hazard or electrical shock! 

 

Maintenance  and  repair  work  must  be  carried  out  only  by  qualified  professionals 
using  original  spare  parts  and  accessories.  Do  not  attempt  to  carry  out  repairs  on 
this appliance yourself! 

 

Connect  this  appliance  to  suitably  earthed  mains  outlets  only.  Ensure  that  your 
mains power supply conforms to the data stated on the nameplate of the appliance. 

Failure to observe this warning may result in a fire hazard or electrical shock! 

 

Table-top device: 
Place this appliance on a sturdy, level and heat-resistant surface to prevent fire 
hazards and accidents. 

 

This appliance is not intended to be used by persons (including children) of limited 
physical, sensory or intellectual abilities, or lacking in experience and/or knowledge, 
unless they are supervised by a person responsible for safety who instructs them in 
the  use  of  the  device.  Children  should  be  supervised  to  ensure  they  will  not  play 
with this appliance. 

 

Do not run the power cord near heat sources, over sharp edges, etc. Always pull on 
the  plug,  not  the  cord,  to  remove  it  from  a  socket-outlet  since  the  cord  might  be 
damaged  as  a  result.  Do  not  allow  cords  to  hang  unsupported.  Route  the  cord  so 
that it will not form a tripping hazard! 

 

When using an extension cord, unwind the cord from the reel to prevent heat build-
up or cord fires, respectively. The socket-and-plug connection must be splash-proof 
and be made of, or coated with, rubber. Each wire must have a cross-section of at 
least 1.5 mm²

Summary of Contents for 29065/H

Page 1: ...9110 K OK SK 2 B 0513 B 0533 B 0572 B 0584 29120 H K OK SK 3 B 0520 B 0521 B 0522 B 0534 B 0573 B 0585 29130 K OK SK 3 B 0523 B 0535 B 0574 B 0586 29140 K OK SK 3 B 0524 B 0536 B 0575 B 0587 29150 K O...

Page 2: ...rding compliance with standards laws and directives 10 2 2 Safety 10 3 Packing transport intermediate storage scope of delivery 11 3 1 Packing 11 3 2 Transport 11 3 3 Intermediate storage 11 3 4 Scope...

Page 3: ...heating bridge with chain fixing 20 8 1 4 Execution quartz compact heating bridge for on site mounting 21 8 1 5 Execution quartz compact heating bridge with height adjustable spiral cable 22 8 2 Dime...

Page 4: ...lly before starting up this appliance On the following pages you will find important notes regarding its operation care and maintenance so that you will be able to enjoy its use for a long time If a m...

Page 5: ...ts only Ensure that your mains power supply conforms to the data stated on the nameplate of the appliance Failure to observe this warning may result in a fire hazard or electrical shock Table top devi...

Page 6: ...intentionally Connecting the unit to the mains with its power switch set to ON may cause accidents Protect this appliance from moisture water spray rain Any penetration of water into the unit will inc...

Page 7: ...sidue remains on the sur face as the latter might cause discoloration or stains Finish by rubbing the surface dry To remove more stubborn or extensive residue a stainless steel cleaning product may be...

Page 8: ...GBA B 0500 1 E BA Page 8 of 27 Mai 18 2020 Last revised 05 2020 Rev 1 Scholl Apparatebau GmbH Co KG Allow the unit to cool down before starting any cleaning work Burn hazard...

Page 9: ...electrical voltage indicates an immediately threatening hazard Failure to observe this warning notice will result in severe physical injury or death CAUTION IMPORTANT Improper use may result in minor...

Page 10: ...o the following Standards laws directives 2014 35 EU Low Voltage Directive 2014 30 EU EMC Directive 2 2 SAFETY This appliance conforms to accepted technical rules and relevant safety codes However pro...

Page 11: ...ar care must be exercised during shipping and handling of this appliance to prevent damage result ing from exposure to excessive force or careless loading unloading Shocks during shipping and handling...

Page 12: ...his appliance Clean the unit before the first use according to chapter Cleaning and care Practice Place mount the unit at a suitable location Heating bridge with height adjustable spiral cable Check o...

Page 13: ...rve the following Faulty equipment must not be taken into operation Legal requirements and the connection conditions of your local power supply company must be fully observed Electrical safety functio...

Page 14: ...warm can be placed under the heat lamp The food must be preheated and must not be deep frozen For switching off after use of the heat lamp Switch off the heat lamp with the switch Let the heat lamp co...

Page 15: ...LEANING AND CARE Before any cleaning maintenance or repair work is carried out the appliance must be disconnected from the mains and de energized To do so it is not enough to set the power switch to O...

Page 16: ...ve or bleaching products i e containing active oxygen chlorine or caustic corrosive constituents abrasive cleaning products such as scouring creams pastes steel wool saponi fied steel wool metal or pl...

Page 17: ...Repairs are not free of charge even within the warranty period if the problem is caused by an operating error or if you have failed to observe any of the following instructions Before any cleaning ma...

Page 18: ...t heat Defective plug electrical cord DANGER Hazardous electrical voltage Pull out the mains plug and bar product from further use To be remedied by an electrical specialist Heat lamp does not heat IR...

Page 19: ...tors Voltage Power 29065 B 0500 650 mm 1 230 V 400 W 29100 B 0510 1 000 mm 2 230 V 800 W 29120 B 0520 1 200 mm 3 230 V 1 200 W 8 1 2 EXECUTION QUARTZ COMPACT HEATING BRIDGE WITH ACRYLIC GLASS COVER Qu...

Page 20: ...length of chain 2 m Model No Art No Length Radiators Voltage Power 29065 K B 0502 650 mm 1 230 V 400 W 29100 K B 0512 1 000 mm 2 230 V 800 W 29110 K B 0513 1 100 mm 2 230 V 800 W 29120 K B 0522 1 200...

Page 21: ...mounting Model No Art No Length Radiators Voltage Power 29065 OK B 0531 650 mm 1 230 V 400 W 29100 OK B 0532 1 000 mm 2 230 V 800 W 29110 OK B 0533 1 100 mm 2 230 V 800 W 29120 OK B 0534 1 200 mm 3 2...

Page 22: ...Black Art No Length Radiators Voltage Power 29065 SK B 0570 B 0582 650 mm 1 230 V 400 W 29100 SK B 0571 B 0583 1 000 mm 2 230 V 800 W 29110 SK B 0572 B 0584 1 100 mm 2 230 V 800 W 29120 SK B 0573 B 0...

Page 23: ...paratebau GmbH Co KG 8 2 DIMENSIONED DRAWINGS Dimensioned drawings are available upon request The information in the dimensioned drawings always take precedence over the summary of the technical data...

Page 24: ...switch black 73 30 56 connection clip 3 pole porcelain 1128G 73 50 03 grommet LA 11 73 69 98 spiral cable draft mechanism black 29xxx SK 73 70 30 connecting cable H05RN F 3G1 with right angle plug 29x...

Page 25: ...our area please contact your local government or community admin istration 9 2 DISPOSAL OF THE APPLIANCE Render the appliance inoperable before disposal Pull the plug out of the socket outlet or arran...

Page 26: ...will be accepted Further warranty information is contained in our Gen eral Terms and Conditions of Sale or can be made available upon request Appliances not produced by ourselves are subject to the w...

Page 27: ...mes Monday Thursday from 7 00 a m till 4 00 p m Fridays from 7 00 a m till 12 15 p m Outside these office hours please communicate your requests per e mail or telefax Scholl Apparatebau GmbH Co KG Zin...

Reviews: