![Schneider Airsystems SLA 10-12 Original Operating Manual Download Page 8](http://html1.mh-extra.com/html/schneider-airsystems/sla-10-12/sla-10-12_original-operating-manual_1213764008.webp)
6
SLA
GB
Adjusting and commissioning:
1. Take hold of the air hose (item 05) in
front of the stopper (item 04) and pull to
the required length.
2. The hose reel locks every 10 / 30 cm and
the hose is retained in that position.
3. Connect the compressed air tool to the
quick-action coupling (item 03) as shown
in Fig. 1a.
Winding up:
1. Disconnect the compressed air tool from
the quick-action coupling (Fig. 1b).
2. Pull the air hose approx. 20 cm beyond
the locking position and then slowly re-
lease at a steady rate.
9
Maintenance
Keep the air hose free of dust, grease and
dirt.
10
Decommissioning
Storage:
Clean, dry, free from dust, above
5° C.
Disposal:
Dispose of packaging / machine
according to valid statutory regulations.
11
Troubleshooting
*For troubleshooting: refer to the information in the "Technical data" chapter“!
***For troubleshooting: read chapter: "Commissioning"!
If necessary, contact our service staff, see last page.
12
Warranty
Basic principle:
complete unit in original
condition / proof of purchase.
Material and production defects are covered
by statutory provisions.
Excluded warranty claims:
Wear or ex-
pendable parts, improper use, overloading /
incorrect pressure, manipulation / inappro-
priate use, inadequate / incorrect / lack of
maintenance or lubrication, bumps / im-
pacts, dust / dirt accumulation, unauthorised
/ incorrect working procedures, incorrect
power supply, impure / insufficiently filtered
compressed air, failure to read the instruc-
tion manual, incorrect operating resources /
materials.
Problem
Cause
Remedy
A Hose does not retract
fully
Hose retracted unevenly
X
Unroll the hose and retract evenly
Spare hose too heavy
X
Use a suitable spare hose
*
Hose stopper displaced
X
Move the hose stopper to the cor-
rect position
***
B Hose retractor leak-
ing
Damaged hose
X
Replace hose
Loose hose clamps
X
Secure hose clamps or replace
Seal on rotary element worn
X
Replace the rotary element seal