II/ 10
KLG / KNG / SNG /PNG
GB
(see Instruction manual, Part 1, Chap-
ter: "Technical data" and the "Intended
use" chapter).
3. Close the magazine slide (item 05) and
allow the catch lever (item 03) (if avail-
able) to engage.
Contact trigger (if available, see Techni-
cal data):
Contact trigger function when trigger lever
(item 02) pulled. Functions when tool is
pressurised.
or
Contact trigger function deactivated when
reversing lever actuated (item 13) (fig. 5a).
Tool is then depressurised.
Compressed air connection:
1. Install an upstream maintenance unit
with filter pressure reducer and mist oil-
er.
2. Press the quick-action coupling of the air
hose onto the plug nipple (item 01)
(Figure 1a).
Operation
:
1. If available: release the interlock
(item 10)
2. Set the required pressure
3. If available: adjust the depth setting
(item 08) (Fig. 4a).
4. Place the trigger safety device (item 06)
or guide plate (item 07) onto the work-
piece and apply pressure firmly.
5. Press the trigger lever (item 02).
6. If available: contact trigger actuated
when trigger lever (item 02) pulled and
trigger safety device (item 06) placed on
the workpiece.
After use:
1. If available:
Secure the interlock (item 10).
2. Disconnect the quick-action coupling
from the plug nipple (item 01)
(Figure 1b).
3. Empty the magazine (item 04).
4. Clean the device dry with compressed
air.
5. Store the device in a secure location.
2.5 Maintenance
L
Regular lubrication is required!
X
Oil using a maintenance unit
with filter pressure reducer and mist oiler.
X
Add oil manually into the
plug nipple (item 01).
X
For long breaks in operation, also oil via
plug nipple (item 01) using special oil for
compressed air tools.
2.6 Decommissioning
Storage:
Clean, dry, dust-free, not below
5° C.
Disposal:
Dispose of the packaging / device
/ materials used according to applicable legal
regulations.
2.7 Troubleshooting
Observe the safety instructions and maintenance instructions!
Problem
Cause
Remedy
A Device does not
function
Trigger lever (item 02) secured
with interlock (item 10)
X
Unlock the trigger lever (item 02)
(Fig. 4a)
Working pressure (flow pres-
sure) too low
X
Increase working pressure (flow
pressure) Observe maximum
working pressure
*
B Compressed air
escaping from the
opening on the
cover
O-ring or seal damaged or dirty
X
Contact Schneider Druckluft
GmbH or an authorised service
partner.
****
Summary of Contents for PNG-PN 25
Page 2: ......
Page 3: ......
Page 4: ......
Page 59: ...KLG KNG SNG PNG II 41 RUS 2 3 X X 1 X X X X X X X X X...
Page 60: ...II 42 KLG KNG SNG PNG RUS L X X X X X X X X X X X X X X X X...
Page 65: ......
Page 66: ......
Page 67: ......