SS 20.600 Ex
– Supplementary instructions for use in explosive atmospheres ATEX Page 11
Assembly (see Figure 6-1):
(1) Insert the open end of the connecting cable into the protective
sleeve (unscrew the screw of the cable bushing) and push it
right up to the cable connector.
(2) Insert the cable connector into the plug of the sensor housing
and tighten the spigot nut manually.
(3) Put the protective sleeve on the plug-in connector and fasten it
by means of the enclosed screws (hexagon sockets 2.5 mm; do
not forget the snap rings) on the housing.
(4) Tighten the nut of the cable bushing (7 Nm).
7 Type plate
The type plate for labeling according to the standards is fixed at the sen-
sor by means of a wire loop.
If required, the customer can attach this plate at another place as long as
its subject (the sensor) can be identified clearly and it is legible and un-
detachable. Examples are:
Mounting it directly at the sensor, e.g. by means of machine
screws through the fixing hole.
Attaching on the adjacent wall next to the sensor or similar
according to EN 60079-0, chapter 29.6.
The side with the warning note "Do not disconnect under
voltage" must remain visible.