background image

10

3.4.1 Measuring in Tension Mode (Cont.)

To insert the process material:
- Place the PROCESS MATERIAL between the two rollers (fig. 3.4.1a).
- Rotate the tension meter by approx. 180 degrees (fig. 3.4.1b). 
  It is important to assure that the PROCESS MATERIAL runs smoothly  
  over the ROLLERS.

To measure the process material:
The DISPLAY now shows the measured tension values.  
Error messages which might be displayed are described in Chapter 3.5.

Damping:
If tension fluctuates, the damping feature should be enabled as described in Chapter 
3.4.5 or the damping factor should be adjusted as described in Chapter 3.4.6. 

To remove the process material:
- Rotate the tension meter by 180 degrees.
- Remove the PROCESS MATERIAL.

3.4.2 Measuring in Speed Mode

Requirements:
Switch on the tension meter (Ch. 3.3.2) and select the speed mode  
(Ch. 3.3.6).

- Insert the PROCESS MATERIAL as described in Chapter 3.4.1.
- Press the ON/OFF/ZERO key.
- The DISPLAY now shows the measured values.

3.4.3 Measuring in Length Mode

While a length measurement is active, “ : ” blinks on the display.  

Continuous measurement
The measurement is performed for as long as PROCESS MATERIAL is run over the roll-
ers.

Requirements:
Switch on the instrument (Ch. 3.3.2) and select the length mode (Ch. 3.3.6) and the unit 
of measure (Ch. 3.3.4).

1. Press and hold the ON/OFF key.
    The length mode settings are indicated on the display.

2. Press the DAMP key until the display shows 

.

3. Insert the PROCESS MATERIAL as described in Chapter 3.4.1.
    This activates the length measurement.
4. Press the ON/OFF/ZERO key to zero the display and start a new measurement.  
    The previous reading is not saved.
5. The measurement stops when you remove the PROCESS MATERIAL as described in  
    Chapter 3.4.1.

Summary of Contents for PT-100

Page 1: ...ension Meter PT Series Model PT 100 PT 100 L Edition PT 01 0 E Operating Instructions Valid as of 15 04 2011 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...Measurement 6 3 2 Operating Elements 6 3 3 Setup 7 3 3 1 Charging the Battery 7 3 3 2 Switch On 7 3 3 3 Switch Off 7 3 3 4 Selecting the Units of Measure 8 3 3 5 Zero Adjustment of the Measuring Position Auto Zero 8 3 3 6 Selecting the Operating Mode 9 3 4 Taking a Measurement 9 3 4 1 Measuring in Tension Mode 9 3 4 2 Measuring in Speed Mode 10 3 4 3 Measuring in Length Mode 10 3 4 4 Displaying th...

Page 3: ...he device Insufficient inspection of device components that are subject to wear Opening the device or improper repair work Disasters caused by the effects of foreign objects or by force majeure 1 1 Notices within the Operating Instructions The fundamental prerequisite for the safe handling of this device and its troublefree opera tion is the knowledge of the basic safety notices and safety instruc...

Page 4: ...amage result ing from misuse The intended use also includes Complying with all notices included in the Operating Instructions and observing all inspection and maintenance works 1 8 Copyright 1 9 Declaration of Conformity RoHs II and WEEE Registration In compliance with the EU Directives 2004 108 EG and 2011 65 EU HANS SCHMIDT CO GmbH is registered in compliance with the German Electrical and Elect...

Page 5: ... 200 FS Measuring Principle Strain gauge bridge Damping Selectable electronic damping moving averaging Display Update Rate 2 times per sec Display 3 digit LCD 9 mm high Power Supply LiPo accumulator 40 h continouse use 3 5 charging time and AC adapter 110 240 V AC with country specific adapters EU USA UK Auto Power Off Automatically after approx 3 min of non use Temperature Range 10 45 C Air Humid...

Page 6: ... may cause permanent damage to the measuring spring and must be avoided under any circumstances 2 3 Unpacking Unpack the tension meter and inspect it for any shipping damage Notices of defect must be filed immediately at the latest within 10 days on receipt of the goods 3 2 Operating Elements fig 3 1 Calibration label option SCHMIDT Quality Seal ID plate with serial number 1 2 3 4 5 fig 3 2 1 MEAS...

Page 7: ...Before you connect the AC adapter verify that the supply voltage is correct 100 V 240 V HANS SCHMIDT Co GmbH provides no warranty or liability for any damage resulting from the use of AC adapters from other manufacturers To charge the battery connect the cable of the AC adapter to the USB port When the battery is fully charged the battery level indicator will show 3 bars The charging time is appro...

Page 8: ...nits of Measure You can set the instrument to cN or g for tension measurements and to m or inch for length measurements The default settings are cN and m Requirement Tension meter switched off as described in Chapter 3 3 3 Press and hold the ON OFF key until the display shows the currently selected units of measure Release the ON OFF key and then press the DAMP key to select the units of measure y...

Page 9: ...splay briefly shows and then Press DAMP and ON OFF Length mode The display briefly shows and then Press DAMP and ON OFF Speed mode The display briefly shows and then The last operating mode used is not stored in memory when you turn off the in strument After power up the tension mode is always active by default 3 4 Taking a Measurement 3 4 1 Measuring in Tension Mode Requirements Switch on the ten...

Page 10: ...itch on the tension meter Ch 3 3 2 and select the speed mode Ch 3 3 6 Insert the PROCESS MATERIAL as described in Chapter 3 4 1 Press the ON OFF ZERO key The DISPLAY now shows the measured values 3 4 3 Measuring in Length Mode While a length measurement is active blinks on the display Continuous measurement The measurement is performed for as long as PROCESS MATERIAL is run over the roll ers Requi...

Page 11: ... no sensor signal is transmitted to the instrument For this purpose remove the magnet from the machine or disconnect the sensor from the instrument Measuring with automatic start stop signal The measurement is performed for a user defined number of machine revolutions fig 3 4 2a MAGNETIC SWITCH MAGNET Recommended switching distance approx 2 mm M5 thread CYLINDER of CIRCULAR KNITTING MACHINE The mo...

Page 12: ...starting from zero The first switching pulse from the MAGNETIC SWITCH also triggers the measurement and display of the filament length 5 After the defined number of revolutions the instrument stops measuring the filament length The DISPLAY shows the measured filament length To start a new measurement zero the display by pressing the ON OFF ZERO key The previous reading is not saved 3 4 4 Displayin...

Page 13: ...e DAMP key The DISPLAY shows 22 1 Damp cN DAMP below the currently measured value To switch off damping Press the DAMP key The DISPLAY shows 12 c N only the currently measured value 3 4 6 Changing the Damping Factor The tension meter is factory preset to a factor of 06 The tension values are thereby averaged for the display in the following way 6 old values 4 new values 10 The damping factor can b...

Page 14: ...y procedure The diameters are given in Chapter 2 Any difference in process material size and rigidity from the standard material may cause a deviation of the accuracy In 95 of all industrial applications the SCHMIDT calibration has been proven to provide the best results and is used for comparative pur poses The tension meter is factory calibrated for a vertical material path fig 3 7 The tension m...

Page 15: ...n on the DISPLAY should be equal to the value of the suspended weight pay attention to the measuring units If this procedure shows a deviation the tension meter has to be returned to the manufac turer for factory calibration The tension meter cannot be calibrated by the user Factory calibration of the tension meter is essential 4 Service and Maintenance The tension meter is easy to maintain Depend...

Page 16: ...uestions and the resulting loss of time or possible misunderstandings please return the instrument with a detailed fault description to our service department Please indicate in your order whether you require an Inspection Certificate 3 1 according to DIN EN 10204 8 Repairs HANS SCHMIDT Co GmbH Schichtstr 16 D 84478 Waldkraiburg Germany Service address Shipping instructions We kindly ask for retur...

Reviews: