background image

10

If you want to store the measured data, you need to assign a Charge / Part  

Number. This information is needed to make up the file name.

3.8.3 User Interface

Display area  
for readings

Maximum value of 
measuring series 

Minimum value of 
measuring series 

Average value of 
measuring series  Standard deviation  

of measuring series 

Current  
actual value 
of measuring 
series 

Batch or
part number 

Number of  
the current  
measurement 

Display of  
data source  
(see ch. 3.8.4)

Name of file 
for measured 
data 

Currently selected 
port (see ch. 3.8.4)

Stops the  
measurement  
series 

Opens the  
Configuration dialog 
box (see ch. 3.8.4)

Summary of Contents for D-2005 Series

Page 1: ...Thickness Gauge D 2005 Series Edition D 2005 01 E Instruction Manual Valid as of 01 11 2020 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...2 3 Unpacking 6 2 4 Optional Accessories 6 3 Measuring 7 3 1 Notices Before Starting Measurement 7 3 2 Operating Elements 7 3 3 Setup 7 3 4 Preparations Before Measuring 8 3 4 1 Setting the Measurement Parameters 8 3 4 2 Checking and Setting the Zero Point 8 3 5 Operating Procedures 8 3 6 Adjusting the Thickness Gauge to Different Materials 9 3 6 1 Changing the Feeler 9 3 6 2 Load Change 9 3 7 Int...

Page 3: ...ion is the knowledge of the basic safety notices and safety instructions These Operating Instructions contain the most important notices for the safe operation of the device These Operating Instructions in particular the safety notices must be observed by any person who works with the device In addition the applicable local rules and regulations for the prevention of accidents must be complied wit...

Page 4: ... works 1 7 Dangers in Handling the Device The device has been designed according to the state of the art and the approved safety standards Nevertheless its use may cause serious or fatal injury to the user or third persons and or an impairment of the device or of other material assets The device may only be applied For its intended use in a faultless condition with regard to the safety requirement...

Page 5: ...r 2 50 kPa and 100 kPa D 2005 HY DIN EN ISO 54540 Toilet tissue 25 2 kPa D 2005 L DIN EN ISO 2589 Leather 0 785 49 1 kPa D 2005 Gi Rubber 10 5 kPa Feeler Calotte D 2005 F DIN 53370 Foil R 30 mm 0 5 N 2 1 Specifications Measuring Range 0 10 mm Option 0 25 mm or 0 50 mm Resolution 0 01 mm Option 0 001 mm D 2000 P and D 2000 F 0 001 mm Standard Accuracy 0 02 mm up to 0 002 mm optional Units of Measur...

Page 6: ...or dial gauge Load table 2 3 Unpacking Unpack the thickness gauge and inspect it for any shipping damage Notices of defect must be announced immediately in writing at the latest within 7 days on receipt of the goods 2 4 Optional Accessories Code R Higher resolution 0 001 instead of 0 01 mm Code E25 Higher measuring range 0 25 mm Code E50 Higher measuring range 0 50 mm P DMG Software for data acqui...

Page 7: ...s gauge on a horizontal flat surface for use Connect the dial gauge to a power supply connect the device with the Sub D9 USB adapter cable to a PC or connect the thickness gauge with the adapter cable and USB AC adapter to a power supply Connect the motor to a power supply Connect the device by using the AC adapter with the power supply Connect the PEDAL SWITCH Switch on the thickness gauge The st...

Page 8: ...contact with the material to be measured You can now perform the test in accordance with the applicable standard 4 The measured value is shown on the digital display 5 Press and hold the SWITCH PEDAL to raise the FEELER 6 Remove the measured material Start the next measurement from step 1 When you are finished measuring return the FEELER to its home position on the MEASURING TABLE 3 4 Preparations...

Page 9: ...ave to be exactly parallel 3 6 2 Load Change On some models see chapter 2 you can change the pressure applied to the mate rial This is done by placing an additional weight on the FIXTURE for ADDITIONAL WEIGHTS Use only original weights supplied by the manufacturer to ensure that the correct measuring force is applied according to the relevant standard 3 8 Software optional 3 8 1 Overview The softw...

Page 10: ...measuring series Minimum value of measuring series Average value of measuring series Standard deviation of measuring series Current actual value of measuring series Batch or part number Number of the current measurement Display of data source see ch 3 8 4 Name of file for measured data Currently selected port see ch 3 8 4 Stops the measurement series Opens the Configuration dialog box see ch 3 8 4...

Page 11: ...two digits H Hour two digits M Minute two digits S Second two digits N Name entered in the Part Charge number box Data acquisition starts as soon as you click the Init measurement button All the data received from then on will be stored To stop the measurement series click the Stop measurement button You can now ac cess the stored data in the program directory 3 8 4 Basic Settings Click the Config...

Page 12: ...vise the shipment in advance by fax or eMail Seit 70 Jahren in aller Welt Postadresse P O B 1154 84464 Waldkraiburg Germany Lieferadresse Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Telefon int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 e mail info hans schmidt com Internet http www hans schmidt com 4 Service and Maintenance The instrument is easy to maintain Dep...

Reviews: