1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded. The relevant requirements 
of the standard EN 14119 must be observed.

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from 
defective mounting or failure to comply with this operating instructions 
manual. The manufacturer shall accept no liability for damages result-
ing from the use of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

ZSD

-

No.

Option

Description

5

2 NO contacts, 1 auxiliary contact (NC) 

6

2 NO contacts, 1 auxiliary contact (NC) with  
additional pushbutton (NO) in the device head

Without mounting angle

H

With mounting angle, metal

Not all component variants, which are possible according to this order 
code, are available.

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

The electromechanical enabling switches (handle switches) of the ZSD 
series are for instance used on industrial robots and automated produc-
tion systems to activate the control functions for hazardous situations 
through other control devices.

An enabling device is an additional manually-operated control device, 
which is used in conjunction with the start equipment and enables a 
machine function, when it is continuously actuated.
The redundant contact configuration enables signal evaluation with 
common safety relay modules. The contact configuration enables the 

signal processing according to ISO 13849-1 PL e (level 2 ↔ 3) or 

 

PL c (level 2 ↔ 1).

2.4  Actuating features

Level

1

2

3

NO contact 1-2

A

NO contact 3-4

A

Auxiliary contact 5-6

A

Suffix:

 White: open; black: closed; 

A

: positive break

The entire concept of the control system, in which the safety 
component is integrated,  
must be validated to the relevant standards.

2.5  Technical data

Standards:

 

ISO 11161, ISO 10218, IEC 60947-5-1,  

IEC 60204-1, ISO 12100, EN 775, EN 60204-1,  

prEN ISO 11161, UL 508*, CSA C22.2  Nr. 14,  

JIS C8201-5-1, ANSI/RIA R 15.06

Ambient temperature:

 

–10 °C … +60 °C (without condensation)

Storage temperature:

 

–40 °C … +80 °C (without condensation)

Rel. air humidity:

 

45 … 85% (no condensation)

Degree of pollution:

 3

Contact resistance:

 

max. 100 mΩ (initial value)

Insulation resistance:

 

100 mΩ (Megger 500 VDC)

Rated impulse withstand voltage:

 

2.5 kV 

 

(without additional pushbutton)

Rated impulse withstand voltage: 

1.5 kV 

 

(with additional pushbutton)

Switching frequency:

 

1.200 s/h

Mechanical life: 

 

- of the NO contact's switch insert:

 

Level 1-2-1: min. 10

6

 operations 

 

Level 1-2-3-1: min. 10

5

 operations

Electrical life: 

 

- of the NO contact's switch insert:

 10

5

 operations (at full load)

Positive break travel:

 

7.4 mm

Minimum required force for positive break:

 

90 N

Resistance to shocks: 

Operation: 100 m/s²,  

Destructive: 1,000 m/s²

Resistance to vibrations: 

Operation: 5 … 55 Hz,  

amplitude 0.5 mm min.; 

destructive: 16.7 Hz,  

amplitude 1.5 mm min.

Connection: 

Screw terminals

Cable section:

 

0.14 … 1.5 mm²

Cable diameter:

 

7 … 13 mm

Cable gland:

 

M 20

Tensile strength of the connection:

 

20 N min.

Recommended tightening torque for the screws: 

Enclosure screws: 

1.2 ± 0.1 Nm 

Strain relief: 4.0 ± 0.3 Nm 

Screw terminals: 0.5 … 0.6 Nm  

Rubber cap screws: –* 

Board screws: –* 

* Do NOT remove!

Protection class:

 IP65

Max. fuse rating:

 

50 A (250 V)

Protection of the contacts: 

external (I

k

 = 1000 A) to EN 60947-5-1,  

Safety fuse 10 A quick blow

Recommended fuse:

 

250 V / 10 A quick-blow (IEC 60127-1)

Weight: 

ZSD5: approx. 210 g;  

ZSD6: approx. 240 g

Electrical specification of the ZSD5/ZSD6 base device 
(without pushbutton)

Rated operating voltage U

e

:

 

250 VAC / VDC

Rated operating current I

e

:

 

3.0 A

Summary of Contents for ZSD5

Page 1: ...y or plant The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific...

Page 2: ...uipment and enables a machine function when it is continuously actuated The redundant contact configuration enables signal evaluation with common safety relay modules The contact configuration enables the signal processing according to ISO 13849 1 PL e level 2 3 or PL c level 2 1 2 4 Actuating features Level 1 2 3 NO contact 1 2 A NO contact 3 4 A Auxiliary contact 5 6 A Suffix White open black cl...

Page 3: ...years B10d value for one channel 100 000 MTTF B d x x h s h 3600 d 10d op op op n 0 1 x nop t cycle For an average annual demand rate of nop 126 720 cycles per year Performance Level PL e can be obtained at maximum load nop average number of activations per year dop average number of operating days per year hop average number of operating hours per day tcycle average demand rate of the safety func...

Page 4: ... relays with positive guided contacts 4 3 Wiring of the ZSD6 L1 N J ZSD 6 KA KB KA KB C B C1 K2 K2 K1 KA KB K1 C2 D F 0 V 24 V A E 23 13 n c 24 14 SRB 301LC X1 X2 S21 S11 S12 S22 A1 C3 G5 E7 B2 D4 H6 F8 External reset button in series with the feedback circuit If the feedback circuit is not required establish a bridge If the reset button is bridged an automatic start takes place shielded C1 channe...

Page 5: ...llowing steps is recommended Check the correct fixing of the enabling switch and the contact elements Remove particles of dust and soiling Check cable entry and connections Damaged or defective components must be replaced 6 Disassembly and disposal 6 1 Disassembly The safety switchgear must be disassembled in a de energised condition only 6 2 Disposal The safety switchgear must be disposed of in a...

Page 6: ...öddinghofe 30 42279 Wuppertal K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com Place and date of issue Wuppertal February 21 2014 Authorised signature Philip Schmersal Managing Director EC Declaration of conformity Translation of the original D...