schmersal TFH 232-11UEDR Operating Instructions Manual Download Page 1

T.FH 232-..UEDR..

Operating instructions
Safety foot switches

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety switchgear. The operating 
instructions must be available in a legible condition and a complete 
version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards to 
be complied with as well as other technical specifications for the selec-
tion, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The safety switchgear must be exclusively used in accordance with the 
versions listed below or for the applications authorised by the manufac-
turer. Detailed information regarding the range of applications can be 
found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is pro-
vided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 
as the instructions regarding mounting, commissioning, operation and 
maintenance are observed.

1.6  Warning about misuse

In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant 
components cannot be excluded. The relevant requirements 
of the standard EN ISO 14119 must be observed.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting

3.1  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3
4.2  Contact variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Set-up and maintenance

5.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Disassembly and disposal

6.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Appendix

7.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

SISS / 10121

1081-EN / F

 

EN

Operating instructions  . . . . . . . . . . . .pages 1 to 6

Translation of the original operating instructions

Summary of Contents for TFH 232-11UEDR

Page 1: ...n accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety r...

Page 2: ...l safety foot switches are mounted with a shield to pro tect against unintentional operation When the foot pedal is actuated to as far as the pressure point the NO contact is closed If in case of danger the pedal is actuated beyond the pressure point then the positive break NC contact is opened and mechanically latched The mechanical latching is realised through a slider and a spring which are mou...

Page 3: ...ty classification Standards EN ISO 13849 1 B10d NC contact 100 000 Service life 20 years MTTF B d x x h s h 3600 d 10d op op op n 0 1 x nop t cycle Specifications can vary depending on the application specific para meters hop dop and tcycle as well as the load If multiple safety components are wired in series the Performance Level to EN ISO 13849 1 will be reduced due to the restricted error detec...

Page 4: ...tested The following conditions must be previously checked and met 1 Check the integrity of the cable entry and connections 2 Check the switch enclosure for damage 3 Check the functionality of the switch by actuating the safety foot switch 5 2 Maintenance The safety function switching of the safety foot switch must be tested at regular intervals Possible soiling accumulated below the foot pedal mu...

Page 5: ...irective Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Shanghai November 10 2014 Authorised signature Jianwei Xu Managing Director EC Declaration of conformity Translation of the original declaration of conformity SCHMERSAL Industrial Switchgear Shanghai Co Ltd Cao Ying Road 3336 201712 Shanghai Qingpu P R ...

Page 6: ...o schmersal com cn Internet http www schmersal com cn K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com 施迈赛工业开关制造 上海 有限公司 地址 上海市青浦区漕盈路3336号 邮编 201712 电话 021 63 75 82 87 传真 021 69 21 43 98 网址 http www schmersal com cn ...

Reviews: