schmersal TFH 232-11UEDR Operating Instructions Manual Download Page 2

2

Operating instructions
Safety foot switches

T.FH 232-..UEDR..

EN

1.7  Exclusion of liability

We shall accept no liability for damages and malfunctions resulting from de-
fective mounting or failure to comply with this operating instructions manual. 
The manufacturer shall accept no liability for damages resulting from the use 
of unauthorised spare parts or accessories.

For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden; 
the manufacturer shall accept no liability for damages resulting from 
such invasive work, arbitrary repairs, conversions and/or modifications 
to the device.

2.  Product description

2.1  Ordering code

This operating instructions manual applies to the following types:

TFH 232-

➀  

1-pedal safety foot switch

No.

Option

Description

11UEDR

1 NO / 1 NC

22UEDR

2 NO / 2 NC

T2FH 232-

➀  

2-pedal safety foot switch

No.

Option

Description

11UEDR/11UEDR

2 NO / 2 NC

22UEDR/22UEDR 4 NO / 4 NC
11/22UEDR

3 NO / 3 NC

22UEDR/11

3 NO / 3 NC

Only if the information described in this operating instructions 
manual are realised correctly, the safety function and therefore 
the compliance with the Machinery Directive is maintained.

2.2  Special versions

For special versions, which are not listed in the order code below 2.1, 
these specifications apply accordingly, provided that they correspond to 
the standard version.

2.3  Destination and use

These robust safety foot switches are particularly suitable for industrial 
applications.  All safety foot switches are mounted with a shield to pro-
tect against unintentional operation.  When the foot pedal is actuated 
to as far as the pressure point, the NO contact is closed.  If, in case 
of danger, the pedal is actuated beyond the pressure point, then the 
positive break NC contact is opened and mechanically latched.

The mechanical latching is realised through a slider and a spring, which 
are mounted in an enclosure. The reset  operation is carried out by 
means of the blue pushbutton, which is located in the top of the cover. 
This button pushes on the slider, which is returned to its original posi-
tion due to this action. The reset button is covered with a rubber cap, 
which protects the inside of the foot switch enclosure against humidity 
and soiling.

Design/Operating principle: overlapping contacts with pressure 
point and latching (UEDR)

Representation

Condition

Function

0

0

1

0

0

0

21

13

22

14

21

13

22

14

21

13

22

14

21

13

22

14

A

A

A

A

Not actuated

No authorised 

operation

Actuated up to 

 pressure  point

Safety release

Pushed-through

No authorised 

operation

Unlock

No authorised 

operation*

*  Switch-on impulse during the unlocking operation must be sup-

pressed by means of measures at control technology level.

For a single-channel connection, a jumper connection must 
be fitted between the contacts (not included in delivery).

The non-safety-related pedal of the 2-pedal safety foot switch 
does not have the overlapping and latching functions.

The user must evaluate and design the safety chain in 
 accordance with the relevant standards and the required 
safety level.

The entire concept of the control system, in which the safety 
component is integrated, must be validated to the relevant 
standards.

Summary of Contents for TFH 232-11UEDR

Page 1: ...n accordance with the versions listed below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety r...

Page 2: ...l safety foot switches are mounted with a shield to pro tect against unintentional operation When the foot pedal is actuated to as far as the pressure point the NO contact is closed If in case of danger the pedal is actuated beyond the pressure point then the positive break NC contact is opened and mechanically latched The mechanical latching is realised through a slider and a spring which are mou...

Page 3: ...ty classification Standards EN ISO 13849 1 B10d NC contact 100 000 Service life 20 years MTTF B d x x h s h 3600 d 10d op op op n 0 1 x nop t cycle Specifications can vary depending on the application specific para meters hop dop and tcycle as well as the load If multiple safety components are wired in series the Performance Level to EN ISO 13849 1 will be reduced due to the restricted error detec...

Page 4: ...tested The following conditions must be previously checked and met 1 Check the integrity of the cable entry and connections 2 Check the switch enclosure for damage 3 Check the functionality of the switch by actuating the safety foot switch 5 2 Maintenance The safety function switching of the safety foot switch must be tested at regular intervals Possible soiling accumulated below the foot pedal mu...

Page 5: ...irective Person authorized for the compilation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Shanghai November 10 2014 Authorised signature Jianwei Xu Managing Director EC Declaration of conformity Translation of the original declaration of conformity SCHMERSAL Industrial Switchgear Shanghai Co Ltd Cao Ying Road 3336 201712 Shanghai Qingpu P R ...

Page 6: ...o schmersal com cn Internet http www schmersal com cn K A Schmersal GmbH Co KG Möddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Telefon 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal com 施迈赛工业开关制造 上海 有限公司 地址 上海市青浦区漕盈路3336号 邮编 201712 电话 021 63 75 82 87 传真 021 69 21 43 98 网址 http www schmersal com cn ...

Reviews: