schmersal TESZ Operating Instructions Manual Download Page 6

6

Operating instructions
Hinge safety switch

TESZ

EN

TESZ-E-EN

7.  EU Declaration of conformity

The currently valid declaration of conformity can be  
downloaded from the internet at www.schmersal.net.

Name of the component:

TESZ

Type:

See ordering code

Description of the component:

Hinge safety switch

Relevant Directives:

Machinery Directive
RoHS-Directive

2006/42/EC
2011/65/EU

Applied standards:

DIN EN 60947-5-1: 2010,
DIN EN ISO 14119: 2014

Person authorized for the compilation  
of the technical documentation:

Oliver Wacker
Möddinghofe 30
42279 Wuppertal

Place and date of issue:

Wuppertal, February 1, 2016

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 
to the applicable European Directives. 

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal 

Phone: 

+49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00
E-Mail: [email protected]
Internet: http://www.schmersal.com

Summary of Contents for TESZ

Page 1: ... below or for the applications authorised by the manufac turer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instruc tions manual the country specific installation standards as well as all prevailing safety regulations and accident prevention ru...

Page 2: ... must evaluate and design the safety chain in accordance with the relevant standards and depending on the required safety level The entire concept of the control system in which the safety component is integrated must be validated to the relevant standards 2 4 Technical data Standards IEC 60947 5 1 BG GS ET 15 Enclosure glass fibre reinforced thermoplastic self extinguishing Hinge TESZ aluminium T...

Page 3: ... are preferably fitted in the upper part of the safety guard to avoid the ingress of dirt and soiling as well as damage to the components In case of painting activities the components must be covered The supplied fixing material must be used We recommend that the fixing screws are painted after the component is fitted Please observe the relevant requirements of the standards EN ISO 12100 EN 953 an...

Page 4: ...res 5 After wiring the wiring compartment must be cleaned i e remove excess cables etc 6 The fixing screws for the wiring compartment cover must be tight ened uniformly with 0 8 Nm tightening torque After the switch has been fitted the switching function and the opening angle of the safety guard must be checked The aperture angle of the NC contacts set in factory is approx 3 5 4 for version 5 appr...

Page 5: ...Positive break travel angle 5 Set up and maintenance 5 1 Functional testing The safety function of the safety components must be tested The following conditions must be previously checked and met 1 Correct fixing of the component 2 Check the integrity of the cable entry and connections 3 Check the switch enclosure for damage 5 2 Maintenance A regular visual inspection and functional test including...

Page 6: ...ation of the technical documentation Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue Wuppertal February 1 2016 Authorised signature Philip Schmersal Managing Director EU Declaration of conformity Original K A Schmersal GmbH Co KG Möddinghofe 30 42279 Wuppertal Germany Internet www schmersal com We hereby certify that the hereafter described components both in their basic desig...

Reviews: