background image

SRB301STV.2 /CCV.2 /PCV.2
SRB301STV.3 /CCV.3 /PCV.3

Operating instructions
Safety-monitoring module

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 
need for the mounting, set-up and commissioning to ensure the safe 
operation and disassembly of the safety-monitoring module. 

T

he operat-

ing instructions must be available in a legible condition and a complete 
version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 
be carried out by trained specialist personnel, authorised by the plant 
operator only.

Please make sure that you have read and understood these operating 
instructions and that you know all applicable legislations regarding 
occupational safety and accident prevention prior to installation and 
putting the component into operation.

The machine builder must carefully select the harmonised standards 
to be complied with as well as other technical specifications for the 
 selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 
execute safety-related functions as part of an entire plant or machine. It 
is the responsibility of the manufacturer of a machine or plant to ensure 
the correct functionality of the entire machinery or plant.

The safety-monitoring module must be exclusively used in accordance 
with the versions listed below or for the applications authorised by the 
manufacturer. Detailed information regarding the range of applications 
can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instruc-
tions manual, the country-specific installation standards as well as all 
prevailing safety regulations and accident prevention rules.

Further technical information can be found in the Schmersal 
catalogues or in the online catalogue on the Internet:  
www.schmersal.net.

The information contained in this operating instructions manual is 
 provided without liability and is subject to technical modifications.

Content

About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 

Target group: authorised qualiied personnel

. . . . . . . . . . . . . . . . . . 1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3  Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 

Safety classiication

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . . 3

Operating principle and settings

5.1  Operating principle after the operating voltage is switched on  . . . . 3
5.2  LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3  Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.4  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.5  Check of the error detection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.6  Notes  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Set-up and maintenance

6.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Disassembly and disposal

7.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Appendix

8.1  Wiring examples  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 

Start coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.3 

Sensor coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

8.4 

Actuator coniguration

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Declaration of conformity

9.1  EC Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

x.000 / März 2013 / v

.A.   -   103002348-EN / C / 2015-07-06 / 

AE-N

r. 4895

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Translation of the original operating instructions

Summary of Contents for SRB301ST/PCV.2

Page 1: ...ust be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the...

Page 2: ...11 S12 and or S21 S22 are opened The safety relevant current paths with the outputs contacts 13 14 23 24 and 33 34 meet the following requirements under observation of a PFH value assessment also refe...

Page 3: ...for electrical connection As far as the electrical safety is concerned the protection against unintentional contact of the connected and therefore electrically interconnected apparatus and the insulat...

Page 4: ...ch the components after electrical discharge Setting the switch see Fig 3 The cross wire short monitoring function factory setting is pro grammed by means of the switch underneath the front cover of t...

Page 5: ...reset button e g welded contacts or manipulations which could lead to an inadvertent restart are detected in this configuration and will result in an inhibition of the operation Automatic start see Fi...

Page 6: ...he control circuits are detected Cross wire shorts between the control circuits are not detected Category 3 PL e to DIN EN ISO 13849 1 possible Dual channel control of magnetic safety switches accordi...

Page 7: ...nt EC Directives 2006 42 EC EC Machinery Directive 2004 108 EC EMC Directive 1995 16 EG EC Lift Directive Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe...

Page 8: ...A Schmersal GmbH Co KG M ddinghofe 30 D 42279 Wuppertal Postfach 24 02 63 D 42232 Wuppertal Phone 49 0 2 02 64 74 0 Telefax 49 0 2 02 64 74 1 00 E Mail info schmersal com Internet http www schmersal c...

Reviews: