Operating instructions

Safety light curtain / safety light grid

SLC440COM Series

SLG440COM Series

EN

5.  Electrical connection

5.1  Wiring diagram

S 1

K 1

K 2

5

1

3

2

4

2

4

1

3

+24 VDC

0 VDC

Not connected (BK)

+24 VDC (BN)

0 VDC (BU)

Release restart (GY)

+24 VDC (BN)

OSSD 2 (BK)

OSSD 1 (WH)

0 VDC (BU)

Not connected (WH)

Protective mode / Automatic active:

Delivery state (Pushbutton S1 not connected)

Restart Interlock (manual reset) active:

Refer to the chapter: operating mode activate restart interlock  

(Pushbutton 1 connected)

K1, K2:

Relay for processing the switching outputs  

OSSD 1,OSSD 2

S1:

Pushbutton for restart (optional)

Summary of Contents for SLC440COM Series

Page 1: ...ion 1 1 2 Target group authorised qualified personnel 1 1 3 Explanation of the symbols used 1 1 4 Appropriate use 2 1 5 General safety instructions 2 1 6 Warning about misuse 2 1 7 Exclusion of liabil...

Page 2: ...ccept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual The manufacturer shall accept no liability for damages re...

Page 3: ...oad inductance 4 0 2H Function protective mode automatic restart interlock setting mode Connection Emitter connector M12 4 pole Receiver connector M12 5 pole Ambient temperature 10 C 50 C Storage temp...

Page 4: ...ction zone interrupted OSSD signal low Green ON state protection zone uninterrupted OSSD signal high 2 9 2 Restart Interlock operation In the operating mode restart interlock the safety switching outp...

Page 5: ...ta or cyan For the parameter setting follow the instructions as described in the section Parameter setting with adapter cable KA 0896 4 Mounting 4 1 General conditions The following guidelines are pro...

Page 6: ...llow operating mode restart interlock 3 Adjust the emitter and receiver so that they are in the middle of the angular range for a green or yellow indication Fix the position with the two screws for ea...

Page 7: ...is exposed to serious injuries To calculate the minimum distances of the safety guards with regards to the hazardous point the EN ISO 13855 and EN ISO 13857 must be observed If an overlap of the prote...

Page 8: ...e 1 Locate the height of the upper edge of the hazardous area a left table column 2 Locate the height of the protection area b upper table row 3 CRO is to be taken from the crossing point of both axes...

Page 9: ...h neighbouring safety light barriers grids of the same type AOPD is excluded If two or more applications are arranged so that mutual interference is possible this should be eliminated with a partition...

Page 10: ...C440COM ER 0970 xx Ls 1024 13 1011 mm 4 8 Dimensions 4 8 1 Dimensions emitter and receiver SLC440COM All measurements in mm 75 A B C 22 2 24 7 7 33 27 8 Type A Protected height 1 B Mounting dimension...

Page 11: ...on description Length 103010816 A K5P M12 S G 5M BK 2 X A 4 69 Female connector M12 5 pole 5 m 103010818 A K5P M12 S G 10M BK 2 X A 4 69 Female connector M12 5 pole 10 m 103010820 A K5P M12 S G 15M BK...

Page 12: ...ed BK 24 VDC BN 0 VDC BU Release restart GY 24 VDC BN OSSD 2 BK OSSD 1 WH 0 VDC BU Not connected WH Protective mode Automatic active Delivery state Pushbutton S1 not connected Restart Interlock manual...

Page 13: ...of the emitter is correctly connected to the emitter and the connecting cable of the receiver is correctly connected to the receiver 4 The double insulation between the light curtain output and an ex...

Page 14: ...Green static Status of OSSD safety switch outputs is ON protection field is clear OSSD OFF Red static Status of OSSD safety switch outputs is OFF the protection field is interrupted Restart interlock...

Page 15: ...003 This device complies with Industry Canada s license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accep...

Page 16: ...205 13144609 Person authorised for the compilation of the technical documentation Oliver Wacker M ddinghofe 30 42279 Wuppertal Place and date of issue M hldorf May 11 2020 Authorised signature Klaus S...

Reviews: