schmersal RSS36-ST-AS Operating Instructions Manual Download Page 1

RSS36-AS

Operating instructions

Safety sensor

EN

1

1.  About this document

1.1  Function

This operating instructions manual provides all the information you 

need for the mounting, set-up and commissioning to ensure the safe 

operation and disassembly of the safety switchgear. The operating 

instructions must be available in a legible condition and a complete 

version in the vicinity of the device.

1.2  Target group: authorised qualified personnel

All operations described in this operating instructions manual must 

be carried out by trained specialist personnel, authorised by the plant 

operator only.

Please make sure that you have read and understood these operating 

instructions and that you know all applicable legislations regarding 

occupational safety and accident prevention prior to installation and 

putting the component into operation.

The machine builder must carefully select the harmonised standards 

to be complied with as well as other technical specifications for the 

selection, mounting and integration of the components.

1.3  Explanation of the symbols used

Information, hint, note:

This symbol is used for identifying useful additional information.

Caution:

 Failure to comply with this warning notice could 

lead to failures or malfunctions.

Warning:

 Failure to comply with this warning notice could 

lead to physical injury and/or damage to the machine.

1.4  Appropriate use

The products described in these operating instructions are developed to 

execute safety-related functions as part of an entire plant or machine. It 

is the responsibility of the manufacturer of a machine or plant to ensure 

the correct functionality of the entire machine or plant.

The safety switchgear must be exclusively used in accordance with 

the versions listed below or for the applications authorised by the 

manufacturer. Detailed information regarding the range of applications 

can be found in the chapter "Product description".

1.5  General safety instructions

The user must observe the safety instructions in this operating instructions 

manual, labelled with the caution or warning symbol above, the country-

specific installation standards as well as all prevailing safety regulations and 

accident prevention rules.

Further technical information can be found in the Schmersal 

catalogues or in the online catalogue on the Internet:  

www.schmersal.net.

The information contained in this operating instructions manual is 

provided without liability and is subject to technical modifications.

There are no residual risks, provided that the safety instructions as well 

as the instructions regarding mounting, commissioning, operation and 

maintenance are observed.

Content

1  About this document

1.1  Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.2 

Target group: authorised qualified personnel

. . . . . . . . . . . . . . . . . .1

1.3  Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.4  Appropriate use  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.5  General safety instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1

1.6  Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

1.7  Exclusion of liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2  Product description

2.1  Ordering code  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.2  Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.3  Comprehensive quality insurance to 2006/42/EC  . . . . . . . . . . . . . .2

2.4  Purpose  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.5  Technical data  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2

2.6 

Safety classification

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3  Mounting

3.1  General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.2  Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3

3.3  Dimensions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.4  Switch distance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

3.5  Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

4  Electrical connection

4.1  General information for electrical connection. . . . . . . . . . . . . . . . . .5

Functions and configuration

5.1  Programming the slave address  . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.2 

Configuration of the safety monitor

  . . . . . . . . . . . . . . . . . . . . . . . . .5

5.3  Status signal "safety release"  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

5.4  Actuator teaching / actuator detection . . . . . . . . . . . . . . . . . . . . . . .5

6  Diagnostic

6.1  LED indications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.2  Error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.3  Diagnostic information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.4  Diagnostic signal periphery error . . . . . . . . . . . . . . . . . . . . . . . . . . .6

6.5  Read-out of the parameter port  . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

7  Set-up and maintenance

7.1  Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

7.2  Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8  Disassembly and disposal

8.1  Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

8.2  Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

9  EU Declaration of conformity

x.000 / 01.2019 / v

.A.   -   103014924 / C / 2020-01-27 / 

AE-Nr

. 1

1919

EN

Operating instructions. . . . . . . . . . . . .pages 1 to 8

Original

Summary of Contents for RSS36-ST-AS

Page 1: ...rding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user must observe the safety instructions in this operating instructions manual labe...

Page 2: ...ition for as long as the safety guard is open The safety switchgears are classified according to ISO 14119 as type 4 switching devices Designs with individual coding are classified as highly coded and...

Page 3: ...de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement 2 6 Safety classification S...

Page 4: ...2 sao 10 10 sar 20 20 With the combination of old sensor new actuator V2 there may be limitations in availability owing to the reduced sao 8 mm This change has no affect on the performance level The s...

Page 5: ...following teach in procedure 1 Switch the safety sensor s voltage supply off and back on 2 Introduce the actuator in the detection range The teach in procedure is signalled at the safety sensor yellow...

Page 6: ...green flashing Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0...

Page 7: ...lar visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable...

Page 8: ...ption of the component Non contact safety sensor with integrated AS i Safety at Work Relevant Directives 2006 42 EC 2014 53 EU 2011 65 EU Machinery Directive RED Directive RoHS Directive Applied stand...