background image

8

EN

RSS36AS-E-EN

Operating instructions

Safety sensor

RSS36-AS

The currently valid declaration of conformity can be  

downloaded from the internet at www.schmersal.net.

Place and date of issue:

Wuppertal, May 26, 2017

Authorised signature

Philip Schmersal

Managing Director

EU Declaration of conformity

Original

K.A. Schmersal GmbH & Co. KG

Möddinghofe 30

42279 Wuppertal

Germany

Internet: www.schmersal.com

We hereby certify that the hereafter described components both in their basic design and construction conform 

to the applicable European Directives. 

Name of the component:

RSS36-AS

Type:

See ordering code

Description of the component:

Non-contact safety sensor with  

integrated AS-i Safety at Work

Relevant Directives:

Machinery Directive

RED-Directive

RoHS-Directive

2006/42/EC

2014/53/EU

2011/65/EU

Applied standards:

EN 60947-5-3:2013,

EN 300 330 V2.1.1:2017,

EN ISO 14119:2013,

EN ISO 13849-1:2015,

EN 61508 parts 1-7:2010,

EN 62061:2005 + AC:2010 + A1:2013 + A2:2015

Notified body for the prototype test:

TÜV Rheinland Industrie Service GmbH

Alboinstr. 56, 12103 Berlin

ID n°: 0035

EC-prototype test certificate:

01/205/5115.01/15

Person authorised for the compilation  

of the technical documentation:

Oliver Wacker

Möddinghofe 30

42279 Wuppertal

9.  EU Declaration of conformity

K. A. Schmersal GmbH & Co. KG

Möddinghofe 30, D - 42279 Wuppertal

Postfach 24 02 63, D - 42232 Wuppertal 

Phone:  +49 - (0)2 02 - 64 74 - 0 

Telefax:  +49 - (0)2 02 - 64 74 - 1 00

E-Mail: [email protected]

Internet: http://www.schmersal.com

Summary of Contents for RSS36-AS

Page 1: ...or for the applications authorised by the manufacturer Detailed information regarding the range of applications can be found in the chapter Product description 1 5 General safety instructions The user...

Page 2: ...smission when the safety guard is opened and maintaining the safe switched off condition for as long as the safety guard is open The safety switchgears are classified according to ISO 14119 as type 4...

Page 3: ...nting 3 1 General mounting instructions Please observe the relevant requirements of the standards ISO 12100 ISO 14119 and ISO 14120 Ensure the safety sensor and actuator is mounted on a flat surface T...

Page 4: ...12 sao 10 10 sar 20 20 With the combination of old sensor new actuator V2 there may be limitations in availability owing to the reduced sao 8 mm This change has no affect on the performance level The...

Page 5: ...following teach in procedure 1 Switch the safety sensor s voltage supply off and back on 2 Introduce the actuator in the detection range The teach in procedure is signalled at the safety sensor yellow...

Page 6: ...n flashing Off 1 static 0 Internal device error periphery error red green flashing Flashes 1 1 static 0 AS i error slave address 0 or communication error red depending on the condition 0 static 0 1 re...

Page 7: ...lar visual inspection and functional test including the following steps is recommended 1 Check the safety function 2 Check the fixing and integrity of the safety switchgear the actuator and the cable...

Page 8: ...on contact safety sensor with integrated AS i Safety at Work Relevant Directives Machinery Directive RED Directive RoHS Directive 2006 42 EC 2014 53 EU 2011 65 EU Applied standards EN 60947 5 3 2013 E...

Reviews: